文献速递肺结节与肺癌

支气管内弹簧圈基准标记用于射波刀立体定向放疗

Endobronchial coil spring fiducial markers for CyberKnife® stereotactic body radiation therapy.
PubMed 文献 · Respirology · 2021-01-05

本研究回顾性评估支气管镜下置入弹簧圈基准标记(cs-FM)用于射波刀追踪肺周围病灶(PPL)的安全性和有效性。共55次操作中置入207枚cs-FM,追踪成功率为93%(65/70 PPL),迁移率8%(16/207),既往放疗区域迁移更常见(P=0.022)。结论认为该操作快速安全、迁移率低,可实现精准SBRT。

要点

  • 支气管镜下cs-FM置入追踪成功率高,PPL追踪成功率达93%。
  • cs-FM迁移率低(8%),但既往放疗区域迁移风险更高(P=0.022)。
  • 操作中位支气管镜时间为31.5分钟,并发症罕见。

核心结论

  • 支气管镜下cs-FM置入是快速安全的操作,迁移率低,可实现精准SBRT。
  • 既往放疗的PPL与更高的迁移率相关。

研究设计与样本

  • 回顾性研究,纳入2015年10月至2019年12月连续接受支气管镜下cs-FM置入的患者,至少一个PPL<25 mm。
  • 共52例患者、55次操作,置入207枚cs-FM于70个PPL。

主要发现

  • 70个PPL中65个(93%)追踪成功。
  • 207枚cs-FM中16枚(8%)发生迁移;既往放疗区域迁移更频繁(P=0.022)。
  • 支气管镜中位操作时间31.5分钟(n=48次操作)。
  • 发生1次支气管痉挛,未观察到其他并发症。

关键数值与推荐

  • PPL<25 mm为纳入标准之一。
  • 33个(47%)PPL行R-EBUS评估,9个(13%)PPL行TBB。

临床怎么用

  • 对于早期不可手术肺癌的SBRT,可考虑支气管镜下cs-FM置入作为标记方式。
  • 对既往放疗区域置入标记需警惕迁移风险。

局限性

  • 回顾性设计。
  • 样本量有限(52例患者)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVE: SBRT is an alternative treatment for early-stage inoperable lung cancer. Metallic FM allow to increase tumour tracking precision by CyberKnife®. Currently used techniques for FM placement have many limitations; transthoracic insertion has a high risk for pneumothorax, endovascular insertion requires expertise and dedicated angiography infrastructure and endobronchial linear-gold FM dislocate frequently. This is the first study to assess the safety and efficacy of cs-FM endobronchial insertion under fluoroscopy with or without R-EBUS assessment. METHODS: We retrospectively evaluated all consecutive patients undergoing endobronchial cs-FM placement for at least one PPL <25 mm between 10.2015 and 12.2019. TBB of the PPL were performed in case of a typical R-EBUS signal. PPL tracking accuracy by CyberKnife, complications, cs-FM migration rate and procedure duration were analysed. RESULTS: A total of 52 patients were treated during 55 procedures and 207 cs-FM were placed in 70 PPL. Tracking was successful for 65 of 70 (93%) PPL. R-EBUS was performed for 33 (47%) PPL and TBB for 9 (13%) PPL. Bronchospasm occurred once and any other complications were observed. Migration of cs-FM occurred in 16 of 207 (8%) cs-FM. Migration was more frequent when the target was in a previously irradiated area (P = 0.022). The median bronchoscopy duration was 31.5 min (n = 48 procedures). CONCLUSION: Bronchoscopic cs-FM placement is a rapid and safe procedure. It is associated with a low migration rate and allows precise SBRT delivery. Previous irradiation of the PPL was associated with a higher migration rate.

来源:Respirology,查看原文。版权归原作者所有。

引用

  1. Casutt A, Noirez L, Bernasconi M, et al. Endobronchial coil spring fiducial markers for CyberKnife® stereotactic body radiation therapy. Respirology. 2021. PMID: 33403786. doi:10.1111/resp.14006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。