MECANO 随机对照试验纳入 1501 例体外循环心脏手术患者,比较体外循环期间低潮气量通气(3 mL/kg,5 次/分,PEEP 5 cm H2O)与不通气策略。

要点

  • 体外循环期间低潮气量通气未降低术后肺部并发症复合终点。

核心结论

  • 体外循环心脏手术中持续低潮气量通气与不通气相比,术后并发症(含死亡、早期呼吸衰竭、第 2 天后通气支持、再插管)无显著差异。

研究设计与样本

  • 单中心随机对照试验,2017 年 5 月至 2019 年 8 月纳入 1501 例心脏手术患者,1:1 随机分为通气策略组(756 例)和不通气策略组(745 例)。
  • 通气策略为体外循环期间低潮气量通气(3 mL/kg,5 次/分,PEEP 5 cm H2O),除体外循环阶段外围术期通气流程标准化。

临床怎么用

  • 体外循环期间低潮气量通气不宜作为所有心脏手术患者的常规推荐以预防术后肺部并发症。
  • 单纯冠状动脉旁路移植术患者可能从体外循环期间低潮气量通气中获益,需个体化评估。

局限性

  • 单中心研究,结果外推需谨慎。
  • 主要终点事件发生率低于预期,可能影响统计效能。
  • 亚组分析为事后分析,证据等级有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Postoperative pulmonary complications are common after cardiac surgery and have been related to lung collapse during cardiopulmonary bypass (CPB). No consensus exists regarding the effects of maintaining mechanical ventilation during CPB to decrease these complications. RESEARCH QUESTION: To determine whether maintaining low-tidal ventilation (3 mL/kg 5 times/min, with positive end expiratory pressure of 5 cm H2O) during CPB (ventilation strategy) was superior to a resting-lung strategy with no ventilation (no ventilation strategy) regarding postoperative pulmonary complications, including mortality. STUDY DESIGN AND METHODS: In a randomized controlled trial, patients undergoing cardiac surgery at a single center from May 2017 through August 2019 were randomized to the ventilation or no ventilation strategy during CPB (1:1 ratio). Apart from the CPB phase, perioperative ventilation procedures were standardized. RESULTS: The study included 1,501 patients (mean age, 68.8 ± 10.3 years; 1,152 (76.7%) men; mean EuroSCORE II, 2.3 ± 2.7). Seven hundred fifty-six patients were in the ventilation strategy group, and no differences existed in baseline characteristics and types of procedures between the two groups. An intention-to-treat analysis yielded no significant difference between the ventilation and no ventilation groups regarding incidence of the primary composite outcome combining death, early respiratory failure, ventilation support beyond day 2, and reintubation, with 112 of 756 patients (14.8%) in the ventilation group vs 133 of 745 patients (17.9%) in the no ventilation group (OR, 0.80; 95% CI, 0.61-1.05; P = .11). Strict per-protocol analyses of 1,338 patients (89.1%) with equally distributed preoperative characteristics yielded similar results (OR, 0.81; 95% CI, 0.60-1.09; P = .16). Post hoc analysis of the subgroup who underwent isolated coronary artery bypass graft procedures (n = 725) showed that the ventilation strategy was superior to the no ventilation strategy regarding the primary outcome (OR, 0.56; 95% CI, 0.37-0.84; P = .005). INTERPRETATION: Among patients undergoing cardiac surgery with CPB, continuation of low tidal volume ventilation was not superior to no ventilation during CPB with respect to postoperative complications, including death, early respiratory failure, ventilation support beyond day 2, and reintubation. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT03098524; URL: www.clinicaltrials.gov.

来源:Chest,查看原文。版权归原作者所有。