吸烟者气道黏液栓与肺气肿在气流受限和低氧血症中的作用
在SPIROMICS研究的400名吸烟者中,57%存在黏液栓、52%存在肺气肿,且可区分黏液主导与肺气肿主导亚组;仅33%高黏液栓评分者有黏液症状。黏液栓评分与肺气肿百分比均独立关联较低的FEV1和外周血氧饱和度(P<0.001),且黏液栓与肺功能的关系在肺气肿较轻者中最强(P<0.001)。高黏液栓评分者CAT评分更差、年急性加重更频繁、6分钟步行距离更短(P<0.001)。
要点
- 吸烟者中无症状黏液栓常见,仅33%高评分者有黏液症状
- 黏液栓评分独立关联较低FEV1和外周血氧饱和度
- 高黏液栓评分者CAT更差、急性加重更多、6分钟步行距离更短
核心结论
- 无症状黏液栓在吸烟者中高度流行,并独立关联肺功能结局。
- 数据支持在临床试验中针对黏液高/肺气肿低的COPD患者使用黏液活性治疗。
研究设计与样本
- 分析SPIROMICS研究参与者的CT肺图像和肺功能。
- 放射科医生对CT肺图像进行黏液栓评分,成像软件自动量化肺气肿百分比。
- 采用回归分析确定黏液栓评分、肺气肿百分比与肺功能之间的未调整和调整后关系。
- 共纳入400名吸烟者。
主要发现
- 400名吸烟者中229名(57%)有黏液栓,207名(52%)有肺气肿,可识别黏液主导和肺气肿主导亚组。
- 高黏液栓评分吸烟者中仅33%有黏液症状。
- 黏液栓评分和肺气肿百分比均独立关联较低的FEV1和外周血氧饱和度(P<0.001)。
- 黏液栓评分与肺功能结局的关系在肺气肿有限的吸烟者中最强(P<0.001)。
- 与低黏液栓评分者相比,高评分者CAT评分更差(17.4±7.7 vs. 14.4±13.3)、年急性加重更频繁(0.75±1.1 vs. 0.43±0.85)、6分钟步行距离更短(329±115 vs. 392±117 m)(P<0.001)。
临床怎么用
- 对COPD吸烟者应关注无症状黏液栓,即使无黏液症状也可能存在。
- 评估黏液栓和肺气肿影像特征有助于识别黏液主导亚组。
- 黏液高/肺气肿低的COPD患者可能是黏液活性治疗的潜在目标人群。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Rationale: The relative roles of mucus plugs and emphysema in mechanisms of airflow limitation and hypoxemia in smokers with chronic obstructive pulmonary disease (COPD) are uncertain.Objectives: To relate image-based measures of mucus plugs and emphysema to measures of airflow obstruction and oxygenation in patients with COPD.Methods: We analyzed computed tomographic (CT) lung images and lung function in participants in the Subpopulations and Intermediate Outcome Measures in COPD Study. Radiologists scored mucus plugs on CT lung images, and imaging software automatically quantified emphysema percentage. Unadjusted and adjusted relationships between mucus plug score, emphysema percentage, and lung function were determined using regression.Measurements and Main Results: Among 400 smokers, 229 (57%) had mucus plugs and 207 (52%) had emphysema, and subgroups could be identified with mucus-dominant and emphysema-dominant disease. Only 33% of smokers with high mucus plug scores had mucus symptoms. Mucus plug score and emphysema percentage were independently associated with lower values for FEV1 and peripheral oxygen saturation (P < 0.001). The relationships between mucus plug score and lung function outcomes were strongest in smokers with limited emphysema (P < 0.001). Compared with smokers with low mucus plug scores, those with high scores had worse COPD Assessment Test scores (17.4 ± 7.7 vs. 14.4 ± 13.3), more frequent annual exacerbations (0.75 ± 1.1 vs. 0.43 ± 0.85), and shorter 6-minute-walk distance (329 ± 115 vs. 392 ± 117 m) (P < 0.001).Conclusions: Symptomatically silent mucus plugs are highly prevalent in smokers and independently associate with lung function outcomes. These data provide rationale for targeting patients with mucus-high/emphysema-low COPD in clinical trials of mucoactive treatments.Clinical trial registered with www.clinicaltrials.gov (NCT01969344).
引用
- Dunican EM, Elicker BM, Henry T, et al. Mucus Plugs and Emphysema in the Pathophysiology of Airflow Obstruction and Hypoxemia in Smokers. Am J Respir Crit Care Med. 2021. PMID: 33180550. doi:10.1164/rccm.202006-2248OC
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。