低强度运动通气与气体交换评估在肺动脉高压风险分层与预后中的临床价值
本研究回顾性分析97例肺动脉高压患者和20例年龄匹配对照的CPET数据,评估低强度自由轮运动(FW)时VE/VCO2和PETCO2反应与峰值氧耗(pVO2)及预后的关系。结果发现FW PETCO2与pVO2相关,且FW PETCO2<28 mmHg是独立死亡预测因子,而FW VE/VCO2无此关联。
要点
- FW PETCO2与pVO2相关(r=0.52,P<0.0001),可识别pVO2>65%预计值。
- FW PETCO2<28 mmHg是肺动脉高压患者死亡的独立预测因子(HR 2.360)。
- FW VE/VCO2与pVO2无关,不能提供预测信息。
核心结论
- 低强度自由轮运动时PETCO2降低与肺动脉高压患者pVO2下降相关,并提供风险分层和预后预测信息。
研究设计与样本
- 回顾性分析97例肺动脉高压患者和20例年龄匹配对照的CPET数据。
- 主要结局为全因死亡。
主要发现
- FW PETCO2与pVO2相关(P<0.0001;r=0.52),FW VE/VCO2与pVO2无关(P=0.13;r=-0.16)。
- ROC分析显示FW PETCO2(AUC=0.659)可预测pVO2>65%预计值,最佳截断值28 mmHg;FW VE/VCO2(AUC=0.587)无预测价值。
- Cox分析显示调整年龄和PAH病因后,FW PETCO2<28 mmHg仍为死亡预测因子(HR: 2.360,95%CI: 1.144-4.866,P=0.020)。
关键数值与推荐
- FW PETCO2最佳截断值为28 mmHg,用于识别pVO2>65%预计值。
- FW PETCO2<28 mmHg与死亡风险增加独立相关(HR 2.360,95%CI 1.144-4.866,P=0.020)。
临床怎么用
- 对于无法完成标准CPET的严重肺动脉高压患者,可考虑低强度自由轮运动评估PETCO2以辅助风险分层。
- FW PETCO2<28 mmHg提示预后不良,需加强监测和管理。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVE: Peak oxygen consumption (pVO2 ), determined from CPET, provides a valuable indication of PAH severity and patient prognosis. However, CPET is often contraindicated in severe PAH and frequently terminated prior to achievement of a sufficient exercise effort. We sought to determine whether in PAH low-intensity [i.e. freewheeling exercise (FW)] exercise reveals abnormal VE /VCO2 and PET CO2 responses that are associated with pVO2 and serve as indices of PAH risk stratification and mortality. METHODS: Retrospective analysis of CPET from 97 PAH patients and 20 age-matched controls was undertaken. FW VE /VCO2 and PET CO2 were correlated with pVO2 % age-predicted. Prognostication analysis was conducted using pVO2 > 65% age-predicted, as known to represent a low mortality risk. Primary outcome was mortality from any cause. RESULTS: FW PET CO2 was correlated with pVO2 (P < 0.0001; r = 0.52), while FW VE /VCO2 was not (P = 0.13; r = -0.16). ROC curve analyses showed that FW PET CO2 (AUC = 0.659), but not FW VE /VCO2 (AUC = 0.587), provided predictive information identifying pVO2 > 65% age-predicted (best cut-off value of 28 mm Hg). By Cox analysis, FW PET CO2 < 28 mm Hg remained a predictor of mortality after adjusting for age and PAH aetiology (HR: 2.360, 95% CI: 1.144-4.866, P = 0.020). CONCLUSION: Low PET CO2 during FW is associated with reduced pVO2 in PAH and provides predictive information for PAH risk stratification and prognostication.
引用
- Sayegh ALC, Silva BM, Ferreira EVM, et al. Clinical utility of ventilatory and gas exchange evaluation during low-intensity exercise for risk stratification and prognostication in pulmonary arterial hypertension. Respirology. 2020. PMID: 33118293. doi:10.1111/resp.13959
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。