超声测量膈肌增厚分数联合最大吸气压对机械通气患者撤机成功的预测价值
该研究纳入73例机械通气>24小时患者,在自主呼吸试验前用超声测量膈肌增厚分数(DTF)并测量最大吸气压(MIP),评估二者单独及联合预测撤机成功的价值。结果显示撤机成功组DTF和MIP均显著高于失败组,DTF≥27.78%联合MIP≥26.5 cmH2O预测撤机成功的AUC为0.920,特异度提高至87.7%。
要点
- DTF≥27.78%预测撤机成功敏感度92.98%、特异度81.25%。
- MIP>26.5 cmH2O预测撤机成功敏感度80.7%、特异度93.75%。
- DTF联合MIP预测撤机成功AUC 0.920,特异度87.7%。
核心结论
- DTF及MIP对机械通气患者撤机时机选择和撤机结果预测具有指导作用。
- 与DTF及MIP单独相比,DTF结合MIP提高了对成功撤机的预测价值。
研究设计与样本
- 研究纳入2018年6月至2019年4月入住皖南医学院弋矶山医院重症医学科机械通气>24小时患者73例。
- 患者符合临床撤机筛查条件后应用低水平PSV法进行自主呼吸试验30分钟。
- 撤机前测量MIP,并用超声测量右侧膈肌位移、吸气末和呼气末膈肌厚度,计算DTF。
主要发现
- 73例患者中撤机成功57例,撤机失败16例。
- 撤机成功组DTF(35%±8%)明显高于撤机失败组(25%±5%),差异有统计学意义(t=6.401,P<0.01)。
- 撤机成功组MIP(34±9 cmH2O)明显高于撤机失败组(23±3 cmH2O),差异有统计学意义(t=7.186,P<0.01)。
- DTF、MIP和膈肌位移的ROC曲线下面积分别为0.907、0.896和0.749。
关键数值与推荐
- 以DTF≥27.78%为标准预测撤机成功,敏感度92.98%,特异度81.25%,AUC为0.907(95% CI:0.816~0.963)。
- 以MIP>26.5 cmH2O为标准预测撤机成功,敏感度80.7%,特异度93.75%,AUC为0.896(95% CI:0.803~0.955)。
- 以DTF≥27.78%且MIP≥26.5 cmH2O为标准预测撤机成功,AUC为0.920(95% CI:0.832~0.971),特异度提高到87.7%,敏感度略降低到87.5%。
临床怎么用
- 撤机前可联合超声测量DTF与MIP,辅助判断机械通气患者撤机时机和预测撤机结局。
- DTF≥27.78%且MIP≥26.5 cmH2O联合标准可提高预测撤机成功的特异度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To evaluate the value of the diaphragmatic thickening fraction (DTF) combined with the maximum inspiratory pressure (MIP) for the prediction of weaning success in mechanically ventilated patients. Methods: Patients admitted to the intensive care unit (ICU) of Yijishan Hospital of Wannan Medical College and on mechanical ventilation for 24 hours from June 2018 to April 2019 were selected as the study subjects. A low-level pressure support ventilation (PSV) method was applied to conduct a spontaneous breathing test (SBT) for 30 minutes after the patients met the screening conditions for clinical weaning; and the patients were weaned when they met the clinical weaning criteria. Before weaning, the patient's MIP was measured. The right hemidiaphragmatic excursion (DE) and the thickness of the diaphragm at the end of inspiration and at the end of exhalation were measured by ultrasound, and the DTF was calculated. The statistical relationship between the DTF, DE and MIP was analyzed. The predictive value for the success of weaning was calculated with the DTF, DE and MIP and was evaluated by the area under the receiver operating characteristic curve (AUC). Results: A total of 73 patients were included in this study, including 57 patients who were successfully weaned, and 16 patients who experienced failure. The DTF of the successful weaning group (35%, 8%) was significantly higher than that of the failed weaning group (25%±5%), and the difference was statistically significant (t=6.401, P<0.01). The MIP (34±9 cmH(2)O) in the successful weaning group was significantly higher than that in the failed weaning group (23±3 cmH(2)O), and the difference was statistically significant (t=7.186, P<0.01). The ROCs for the DTF, MIP, and diaphragmatic displacement were 0.907, 0.896, and 0.749, respectively. A DTF ≥ 27.78%, with a sensitivity of 92.98%, a specificity of 81.25%, and an AUC of 0.907 (95% CI: 0.816-0.963), was used as the standard to predict the success of weaning. An MIP>26.5 cmH(2)O, with a sensitivity of 80.7%, a specificity of 93.75%, and an AUC of 0.896 (95% CI: 0.803-0.955), was used as the standard to predict the success of weaning. The AUC of DTF ≥ 27.78% and MIP ≥ 26.5 cmH(2)O was 0.920 (95% CI:0.832-0.971), and the specificity increased to 87.7%, but the sensitivity was slightly reduced to 87.5%. Conclusions: The DTF and MIP play a crucial role in determining the appropriate time and predicting the outcome of weaning of mechanical ventilation patients. Compared with the DTF and MIP alone, the DTF combined with MIP greatly improved the accuracy of predicting successful weaning. 目的: 探讨膈肌增厚分数与最大吸气压对机械通气患者撤机的预测价值。 方法: 选择2018年6月至2019年4月入住皖南医学院弋矶山医院重症医学科机械通气>24 h患者为研究对象,在患者符合临床撤机筛查条件后应用低水平PSV法进行自主呼吸试验(SBT)30 min,对符合临床撤机标准者进行撤机。撤机前测量患者最大吸气压(MIP),使用超声测量右侧膈肌位移(DE)、吸气末和呼气末膈肌厚度,计算膈肌增厚分数(DTF)。统计分析DTF、膈肌位移和MIP与撤机结果之间的关系,采用AUC(ROC)分别评价DTF、膈肌位移和MIP对撤机成功的预测价值。 结果: 共73例患者纳入本研究,其中撤机成功57例,撤机失败16例。撤机成功组的DTF(35%±8%)明显高于撤机失败组的DTF(25%±5%),差异有统计学意义(t=6.401,P<0.01)。撤机成功组的MIP[(34±9)cmH(2)O,1 cmH(2)O=0.098 kPa]明显高于撤机失败组的MIP[(23±3)cmH(2)O],差异有统计学意义(t=7.186,P<0.01)。DTF、MIP和膈肌位移的受试者工作特征曲线(ROC)分别是0.907、0.896和0.749。以DTF≥27.78%为标准预测撤机成功,敏感度92.98%,特异度81.25%,ROC曲线下面积为0.907(95% CI:0.816~0.963)。以MIP>26.5 cmH(2)O为标准预测撤机成功,敏感度80.7%,特异度93.75%,ROC曲线下面积为0.896(95% CI:0.803~0.955)。以DTF≥27.78%且MIP≥26.5 cmH(2)O为标准预测撤机成功,其ROC曲线下面积为0.920(95% CI: 0.832~0.971),特异度提高到87.7%,但敏感度略降低到87.5%。 结论: DTF及MIP对机械通气患者撤机时机选择和撤机结果预测具有指导作用,与DTF及MIP相比,DTF结合MIP提高了对成功撤机的预测价值。.
引用
- Zhang P, Jiang HJ, Zhou Q, et al. [The predictive value of ultrasonic measurement of the diaphragmatic thickening fraction combined with the maximal inspiratory pressure in mechanical ventilation patients]. Zhonghua Jie He He Hu Xi Za Zhi. 2020. PMID: 32894912. doi:10.3760/cma.j.cn112147-20200417-00513
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。