COVID-19大流行前早期急性呼吸窘迫综合征的顺应性表型
该研究对一项大型跨国流行病学研究中的1117例接受有创机械通气的ARDS患者进行二次分析,评估呼吸系统顺应性(Crs)与低氧血症程度及预后的关系。结果显示Crs范围广泛,约八分之一患者Crs保留,且PaO2/FiO2与Crs几乎完全分离;较低的Crs与较高的住院死亡率独立相关。
要点
- 非COVID-19的ARDS患者中Crs范围广泛,约12%患者Crs≥50 ml/cm H2O(L型表型)。
- PaO2/FiO2与Crs几乎完全分离,43%的L型表型患者PaO2/FiO2<150。
- 较低的Crs与较高的住院死亡率独立相关,且Crs-死亡率关系缺乏明确转折阈值。
核心结论
- 在COVID-19大流行前的ARDS患者中观察到广泛的Crs范围,约八分之一患者Crs保留。
- PaO2/FiO2与Crs几乎完全分离。
- 较低的Crs与较高的住院死亡率独立相关,且Crs-死亡率关系缺乏明确转折阈值。
研究设计与样本
- 对一项大型跨国流行病学研究中的ARDS患者进行二次分析。
- 纳入1117例接受有创机械通气且采用控制模式通气的ARDS患者。
主要发现
- 中位Crs为30(四分位距23-40)ml/cm H2O。
- 136例(12%)患者Crs保留(≥50 ml/cm H2O,L型表型),827例(74%)患者Crs较差(<40 ml/cm H2O,H型表型)。
- H型表型患者病情更重、合并症更多,住院死亡率更高(32% vs. 45%;P < 0.05)。
- 136例L型表型患者中58例(43%)PaO2/FiO2 < 150。
- 在多变量校正分析中,Crs与住院死亡率独立相关(每增加1 ml/cm H2O的校正比值比0.988;95%置信区间0.979-0.996;P = 0.005)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Rationale: A novel model of phenotypes based on set thresholds of respiratory system compliance (Crs) was recently postulated in context of coronavirus disease (COVID-19) acute respiratory distress syndrome (ARDS). In particular, the dissociation between the degree of hypoxemia and Crs was characterized as a distinct ARDS phenotype.Objectives: To determine whether such Crs-based phenotypes existed among patients with ARDS before the COVID-19 pandemic and to closely examine the Crs-mortality relationship.Methods: We undertook a secondary analysis of patients with ARDS, who were invasively ventilated on controlled modes and enrolled in a large, multinational, epidemiological study. We assessed Crs, degree of hypoxemia, and associated Crs-based phenotypic patterns with their characteristics and outcomes.Measurements and Main Results: Among 1,117 patients with ARDS who met inclusion criteria, the median Crs was 30 (interquartile range, 23-40) ml/cm H2O. One hundred thirty-six (12%) patients had preserved Crs (≥50 ml/cm H2O; phenotype with low elastance ["phenotype L"]), and 827 (74%) patients had poor Crs (<40 ml/cm H2O; phenotype with high elastance ["phenotype H"]). Compared with those with phenotype L, patients with phenotype H were sicker and had more comorbidities and higher hospital mortality (32% vs. 45%; P < 0.05). A near complete dissociation between PaO2/FiO2 and Crs was observed. Of 136 patients with phenotype L, 58 (43%) had a PaO2/FiO2 < 150. In a multivariable-adjusted analysis, the Crs was independently associated with hospital mortality (adjusted odds ratio per ml/cm H2O increase, 0.988; 95% confidence interval, 0.979-0.996; P = 0.005).Conclusions: A wide range of Crs was observed in non-COVID-19 ARDS. Approximately one in eight patients had preserved Crs. PaO2/FiO2 and Crs were dissociated. Lower Crs was independently associated with higher mortality. The Crs-mortality relationship lacked a clear transition threshold.
引用
- Panwar R, Madotto F, Laffey JG, et al. Compliance Phenotypes in Early Acute Respiratory Distress Syndrome before the COVID-19 Pandemic. Am J Respir Crit Care Med. 2020. PMID: 32805143. doi:10.1164/rccm.202005-2046OC
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。