急性呼吸衰竭幸存者床旁吞咽评估决策树算法的开发

Development of an Accurate Bedside Swallowing Evaluation Decision Tree Algorithm for Detecting Aspiration in Acute Respiratory Failure Survivors.
PubMed 文献 · Chest · 2020-07-25

多中心前瞻性研究纳入机械通气≥48小时后拔管的急性呼吸衰竭幸存者213例,以柔性内镜吞咽评估(FEES)为金标准,评估床旁吞咽评估(BSE)识别误吸的准确性并构建决策树算法。33%患者至少一种FEES食团稠度试验出现误吸,稀液体最常见(27%)。BSE决策树算法将误吸检测准确率提升至81%、敏感度95%、阴性预测值97%,尚需进一步验证。

要点

  • 拔管后BSE识别误吸敏感度较高但准确率仅52%,单用不足以排除风险。
  • 五变量BSE决策树算法准确率81%、敏感度95%、阴性预测值97%,可辅助识别高危患者。
  • 稀液体为最常见误吸稠度(27%),评估时应重点关注。

核心结论

  • BSE识别误吸的准确性有限,基于五变量的BSE决策树算法可提升检测准确性,但尚需进一步验证。

研究设计与样本

  • 多中心前瞻性研究,纳入机械通气≥48小时后拔管的急性呼吸衰竭幸存者,最终分析213例。
  • 研究流程为床旁吞咽评估(BSE)后行金标准柔性内镜吞咽评估(FEES);拔管至BSE中位时间25小时(四分位距21-45小时),FEES在BSE后1小时完成(四分位距0.5-2小时)。

主要发现

  • 33%(70/213;95% CI,26.6%-39.2%)的患者在至少一种FEES食团稠度试验中发生误吸。
  • 稀液体为最常见误吸稠度:27%(54/197;95% CI,21%-34%)。
  • BSE检测任何误吸的准确率为52%(95% CI,45%-58%),敏感度83%(95% CI,74%-92%),阴性预测值81%(95% CI,72%-91%)。
  • 采用递归分割分析构建的五变量BSE决策树算法将误吸检测准确率提高至81%(95% CI,75%-87%),敏感度95%(95% CI,90%-98%),阴性预测值97%(95% CI,95%-99%)。

临床怎么用

  • 拔管后可用BSE初筛误吸风险,但因其准确率有限,阴性结果不宜单独作为排除误吸的依据。
  • 决策树算法有助于识别误吸高危患者,但原文提示尚需进一步验证后方可用于临床决策。

局限性

  • 原文未系统列出局限性;作者指出决策树算法尚需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The bedside swallowing evaluation (BSE) is an assessment of swallowing function and airway safety during swallowing. After extubation, the BSE often is used to identify the risk of aspiration in acute respiratory failure (ARF) survivors. RESEARCH QUESTION: We conducted a multicenter prospective study of ARF survivors to determine the accuracy of the BSE and to develop a decision tree algorithm to identify aspiration risk. STUDY DESIGN AND METHODS: Patients extubated after ≥ 48 hours of mechanical ventilation were eligible. Study procedures included the BSE followed by a gold standard evaluation, the flexible endoscopic evaluation of swallowing (FEES). RESULTS: Overall, 213 patients were included in the final analysis. Median time from extubation to BSE was 25 hours (interquartile range, 21-45 hours). The FEES was completed 1 hour after the BSE (interquartile range, 0.5-2 hours). A total of 33% (70/213; 95% CI, 26.6%-39.2%) of patients aspirated on at least one FEES bolus consistency test. Thin liquids were the most commonly aspirated consistency: 27% (54/197; 95% CI, 21%-34%). The BSE detected any aspiration with an accuracy of 52% (95% CI, 45%-58%), a sensitivity of 83% (95% CI, 74%-92%), and negative predictive value (NPV) of 81% (95% CI, 72%-91%). Using recursive partitioning analyses, a five-variable BSE-based decision tree algorithm was developed that improved the detection of aspiration with an accuracy of 81% (95% CI, 75%-87%), sensitivity of 95% (95% CI, 90%-98%), and NPV of 97% (95% CI, 95%-99%). INTERPRETATION: The BSE demonstrates variable accuracy to identify patients at high risk for aspiration. Our decision tree algorithm may enhance the BSE and may be used to identify patients at high risk for aspiration, yet requires further validation. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT02363686; URL: www.clinicaltrials.gov.