文献速递肺栓塞与肺血管病

肺动脉球囊成形术后运动性肺动脉高压与运动不耐受的关系

Exercise intolerance in chronic thromboembolic pulmonary hypertension after pulmonary angioplasty.
PubMed 文献 · Eur Respir J · 2020-07-09

该研究纳入249例经肺动脉球囊成形术(BPA)治疗后静息平均肺动脉压(mPAP)正常的慢性血栓栓塞性肺动脉高压(CTEPH)患者,行心肺运动试验联合右心导管检查。结果显示,运动性肺动脉高压组(mPAP-CO斜率>3.0)峰值氧耗量更低,且mPAP-CO斜率与峰值氧耗量负相关、与通气效率斜率正相关。

要点

  • BPA术后静息mPAP正常的CTEPH患者中,运动性肺动脉高压与峰值氧耗量降低相关。
  • mPAP-CO斜率>3.0定义运动性肺动脉高压,与通气效率下降相关。
  • 静息血流动力学正常不代表运动能力正常,需关注运动性肺动脉高压。

核心结论

  • BPA术后静息肺动脉压正常的CTEPH患者中,存在运动性肺动脉高压者表现出运动能力受损和通气效率下降。

研究设计与样本

  • 单中心研究纳入249例CTEPH患者(平均年龄63±14岁,男女比62:187),均经BPA治疗且静息mPAP<25 mmHg、肺动脉楔压≤15 mmHg,行心肺运动试验联合右心导管检查。

主要发现

  • 运动性肺动脉高压组(n=116)静息肺血管阻力显著高于非运动性肺动脉高压组(n=133)。
  • 运动性肺动脉高压组峰值氧耗量低于非运动性肺动脉高压组(13.5±3.8 vs 16.6±4.7 mL·min-1·kg-1,p<0.001)。
  • mPAP-CO斜率与峰值氧耗量负相关(r=-0.45,p<0.001),与分钟通气量/二氧化碳输出斜率正相关(r=0.39,p<0.001)。

关键数值与推荐

  • 运动性肺动脉高压定义为运动时mPAP-CO斜率>3.0。
  • 静息mPAP<25 mmHg且肺动脉楔压≤15 mmHg定义为静息血流动力学正常。

临床怎么用

  • 对BPA术后静息肺动脉压正常的CTEPH患者,若仍有运动后气短,应评估运动性肺动脉高压。
  • 心肺运动试验联合右心导管可识别运动性肺动脉高压,指导进一步评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Exercise pulmonary hypertension is common in patients with chronic thromboembolic pulmonary hypertension (CTEPH) who experience shortness of breath during exercise and reduced exercise capacity despite normalised pulmonary arterial pressure (PAP) at rest; however, the relationship between exercise pulmonary hypertension and exercise capacity remains unclear. Here we aimed to determine whether exercise pulmonary hypertension is related to exercise capacity and ventilatory efficiency in CTEPH patients with normalised resting haemodynamics after pulmonary balloon angioplasty (BPA). PATIENTS AND METHODS: In total, 249 patients with CTEPH treated with BPA (mean±sd age 63±14 years; male:female 62:187) with normal mean PAP (mPAP) (<25 mmHg) and pulmonary arterial wedge pressure (≤15 mmHg) at rest underwent cardiopulmonary exercise testing with right heart catheterisation. mPAP-cardiac output (CO) during exercise was plotted using multipoint plots. Exercise pulmonary hypertension was defined by a mPAP-CO slope >3.0. RESULTS: At rest, pulmonary vascular resistance was significantly higher in the exercise pulmonary hypertension group (n=116) than in the non-exercise pulmonary hypertension group (n=133). Lower peak oxygen consumption (13.5±3.8 versus 16.6±4.7 mL·min-1·kg-1; p<0.001) was observed in the former group. The mPAP-CO slope was negatively correlated with peak oxygen consumption (r= -0.45, p<0.001) and positively correlated with the minute ventilation versus carbon dioxide output slope (r=0.39, p<0.001). CONCLUSIONS: Impaired exercise capacity and ventilatory efficiency were observed in patients with CTEPH who had normalised PAP at rest but exercise pulmonary hypertension.

来源:Eur Respir J,查看原文。版权归原作者所有。

引用

  1. Kikuchi H, Goda A, Takeuchi K, et al. Exercise intolerance in chronic thromboembolic pulmonary hypertension after pulmonary angioplasty. Eur Respir J. 2020. PMID: 32312861. doi:10.1183/13993003.01982-2019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。