胸部CT管腔内黏液栓与肺功能、生活质量及慢阻肺表型的关联
研究从COPDGene队列随机选取100例无COPD吸烟者和400例COPD吸烟者,在基线和5年随访时通过吸气相CT识别管腔内黏液栓。COPD患者中黏液栓患病率高于无COPD者(25% vs 10%,P=.001),且与FEV1%预计值降低、SGRQ评分升高及肺气肿定量指标相关。
要点
- COPD患者CT管腔内黏液栓患病率高于无COPD吸烟者(25% vs 10%)。
- 黏液栓与FEV1%预计值降低(估计值-6.1)和SGRQ评分升高(估计值4.9)独立相关。
核心结论
- 在COPD患者中,CT识别的管腔内黏液栓与气流阻塞、更差的健康相关生活质量及肺气肿表型相关。
- 该影像特征可能补充当前对COPD慢性黏液高分泌的临床评估。
研究设计与样本
- 从COPDGene研究中随机选取100例无COPD吸烟者和400例COPD吸烟者。
- 在基线和5年随访时通过吸气相CT视觉识别管腔内黏液栓。
- 采用线性和logistic多变量分析评估黏液栓与FEV1、SGRQ评分、肺气肿(%LAA-950)及慢性支气管炎的关系。
主要发现
- 总体111例(22%)存在管腔内黏液栓。
- COPD患者黏液栓患病率高于无COPD者(25% vs 10%,P=.001)。
- 在COPD患者中,黏液栓与FEV1%预计值(估计值-6.1;SE 2.1;P=.004)和SGRQ评分(估计值4.9;SE 2.4;P=.04)显著相关。
- 黏液栓与log %LAA-950相关(估计值0.43;SE 0.16;P=.007),与慢性支气管炎的关系未达统计学显著性(P=.07)。
临床怎么用
- 胸部CT发现的管腔内黏液栓可提示COPD患者气流阻塞更重和生活质量更差。
- 该影像特征可作为评估COPD慢性黏液高分泌的补充信息。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Mucous exudates occluding the lumen of small airways are associated with reduced lung function and mortality in subjects with COPD; however, luminal plugs in large airways have not been widely studied. We aimed to examine the associations of chest CT scan-identified luminal plugging with lung function, health-related quality of life, and COPD phenotypes. METHODS: We randomly selected 100 smokers without COPD and 400 smokers with COPD from the COPDGene Study. Luminal plugging was visually identified on inspiratory CT scans at baseline and 5-year follow-up. The relationships of luminal plugging to FEV1, St. George's Respiratory Questionnaire (SGRQ) score, emphysema on CT scan (defined as the percentage of low attenuation area < 950 Hounsfield units [%LAA-950]), and chronic bronchitis were assessed using linear and logistic multivariable analyses. RESULTS: Overall, 111 subjects (22%) had luminal plugging. The prevalence of luminal plugging was higher in subjects with COPD than those without COPD (25% vs 10%, respectively; P = .001). In subjects with COPD, luminal plugging was significantly associated with FEV1 % predicted (estimate, -6.1; SE, 2.1; P = .004) and SGRQ score (estimate, 4.9; SE, 2.4; P = .04) in adjusted models. Although luminal plugging was associated with log %LAA-950 (estimate, 0.43; SE, 0.16; P = .007), its relationship with chronic bronchitis did not reach statistical significance (P = .07). Seventy-three percent of subjects with COPD with luminal plugging at baseline had it 5 years later. CONCLUSIONS: In subjects with COPD, CT-identified luminal plugging is associated with airflow obstruction, worse health-related quality of life, and emphysema phenotype. This imaging feature may supplement the current clinical assessment of chronic mucus hypersecretion in COPD.
引用
- Okajima Y, Come CE, Nardelli P, et al. Luminal Plugging on Chest CT Scan: Association With Lung Function, Quality of Life, and COPD Clinical Phenotypes. Chest. 2020. PMID: 32017932. doi:10.1016/j.chest.2019.12.046
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。