文献速递哮喘

强迫振荡技术评估支气管舒张反应识别哮喘控制不佳的敏感性优于肺量计

Bronchodilator Response Assessed by the Forced Oscillation Technique Identifies Poor Asthma Control With Greater Sensitivity Than Spirometry.
PubMed 文献 · Chest · 2020-01-23

结果显示FOT识别BDR更频繁(54% vs 27%),且反应性参数(X5、AX)与哮喘控制相关,识别控制不佳的敏感性更高(AX 69% vs 肺量计41%)。

要点

  • FOT识别BDR的频率高于肺量计(54% vs 27%)。
  • X5和AX与哮喘控制相关,R5无此关联。
  • AX识别哮喘控制不佳的敏感性高于肺量计(69% vs 41%)。

核心结论

  • FOT评估的BDR可识别哮喘控制不佳,反应性参数比肺量计更敏感。

主要发现

  • FOT识别BDR的比例为54%,肺量计为27%。
  • X5和AX与肺量计BDR相关(χ2,P < .01),且与哮喘控制相关(X5:rs = -0.36,P < .01;AX:rs = 0.34,P = .01)。
  • AX识别哮喘控制不佳的比例为69%,肺量计为41%。

关键数值与推荐

  • BDR的肺量计定义依据标准推荐,FOT定义基于健康成人BDR的95百分位。

临床怎么用

  • FOT可作为肺量计的补充用于哮喘临床管理,尤其反应性参数有助于识别控制不佳。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Persistent bronchodilator response (BDR) following diagnosis of asthma is an underrecognized treatable trait, associated with worse lung function and asthma control. The forced oscillation technique (FOT) measures respiratory system impedance, and BDR cutoffs have been proposed for healthy adults; however, the relevance in asthma is unknown. We compared BDR cutoffs, using FOT and spirometry, in asthma and the relationship with asthma control. METHODS: Data from patients with asthma who withheld bronchodilator medication for at least 8 h before a tertiary airway clinic visit were reviewed. All subjects performed FOT and spirometry before and after salbutamol administration, and completed the Asthma Control Test. FOT parameters examined included respiratory system resistance (R5) and reactance (X5) at 5 Hz, and area under the reactance curve (AX). BDR was defined by standard recommendations for spirometry and based on the 95th percentile of BDR in healthy adults for FOT. RESULTS: Fifty-two subjects (18 men; mean age, 53 ± 18 years) were included. BDR was identified more frequently by FOT than spirometry (54% vs 27% of subjects). BDR assessed by X5 and AX, but not R5, was associated with spirometric BDR (χ2, P < .01) and correlated with asthma control (X5: rs = -0.36, P < .01; AX: rs = 0.34, P = .01). BDR measured by reactance parameters identified more subjects with poor asthma control than did spirometry (AX, 69% vs spirometry, 41%). CONCLUSIONS: BDR assessed by FOT can identify poor asthma control. Reactance parameters were more sensitive in identifying poor asthma control than spirometry, supporting the use of FOT to complement spirometry in the clinical management of asthma.

来源:Chest,查看原文。版权归原作者所有。

引用

  1. Cottee AM, Seccombe LM, Thamrin C, et al. Bronchodilator Response Assessed by the Forced Oscillation Technique Identifies Poor Asthma Control With Greater Sensitivity Than Spirometry. Chest. 2020. PMID: 31982392. doi:10.1016/j.chest.2019.12.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。