CT气道计数与哮喘严重程度及气道结构功能的关系
研究通过支气管舒张后吸气相CT测量70例哮喘患者的CT可见气道总数(TAC),并评估其与哮喘严重程度、气道形态、肺功能及MRI通气的关系。结果显示TAC在GINA 4和5级患者中较GINA 1-3级显著减少,且TAC独立预测FEV1和气道壁面积百分比。
要点
- 重症哮喘患者CT可见气道总数较轻度患者显著减少。
- TAC独立预测FEV1和气道壁面积百分比。
- 亚亚段气道缺失≥10个与更差的气道壁厚度和通气缺陷相关。
核心结论
- TAC在哮喘严重程度更高的参与者中显著减少,并与气道壁厚度和通气缺陷相关。
研究设计与样本
- 研究纳入70例哮喘患者,包括15例GINA 1-3级、19例GINA 4级和36例GINA 5级,均接受支气管舒张后吸气相CT、肺功能及超极化3He MRI。
主要发现
- 与GINA 1-3级相比,TAC在GINA 4级(P=0.03)和GINA 5级(P=0.045)显著减少。
- 70例中5例(2例GINA 4级和3例GINA 5级)存在终末气道腔内闭塞。
- 70例中69例存在亚亚段气道CT不可见或缺失,最常见的缺失数量为10个。
- 缺失亚段≥10个的参与者气道壁面积百分比(P<0.0001)、管腔面积(P<0.0001)和通气缺陷百分比(P=0.03)均劣于缺失<10个者。
- 多变量模型中,TAC独立预测FEV1(标准化回归系数=0.50;P=0.001;R2=0.27;P=0.003)和气道壁面积百分比(标准化回归系数=-0.53;P<0.0001;R2=0.32;P=0.0001)。
临床怎么用
- CT测量的TAC可作为评估哮喘气道结构改变和疾病严重程度的影像学指标。
- 亚亚段气道缺失数量可能提示气道壁增厚和通气缺陷的加重。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Rationale: In patients with asthma, X-ray computed tomography (CT) has provided evidence of thickened airway walls and airway occlusions, but the total number of CT-visible airways and its relationship with disease severity is unknown.Objectives: To measure CT total airway count (TAC) in asthma and evaluate relationships with asthma severity, airway morphology, pulmonary function, and magnetic resonance imaging (MRI) ventilation.Methods: Participants underwent post-bronchodilator inspiratory CT, and prebronchodilator and post-bronchodilator spirometry and hyperpolarized 3He MRI. CT TAC was quantified as the sum of airways in the segmented airway tree, and airway wall area percent (WA%) and lumen area were measured. MRI ventilation abnormalities were quantified as the ventilation defect percent.Measurements and Main Results: We evaluated 70 participants, including 15 Global Initiative for Asthma (GINA) steps 1 to 3, 19 GINA 4, and 36 GINA 5 participants with asthma. As compared with GINA 1 to 3, TAC was significantly diminished in GINA 4 (P = 0.03) and GINA 5 (P = 0.045). Terminal airway intraluminal occlusion was present in 5 (2 GINA 4 and 3 GINA 5) of 70 participants. Sub-subsegmental airways were CT-invisible or missing in 69 out of 70 participants; the most common number of missing sub-subsegments was 10. Participants with ≥10 missing subsegments had worse WA% (P < 0.0001), lumen area (P < 0.0001), and ventilation defect percent (P = 0.03) than those with <10 missing subsegments. In a multivariable model, TAC (standardized regression coefficient = 0.50; P = 0.001) independently predicted FEV1 (R2 = 0.27; P = 0.003) and, in a separate model, TAC (standardized regression coefficient = -0.53; P < 0.0001) independently predicted airway WA% (R2 = 0.32; P = 0.0001).Conclusions: TAC was significantly diminished in participants with greater asthma severity and was related to airway wall thickness and ventilation defects. Fewer airways in severe than in mild asthma challenges our understanding of airway disease in asthma.Clinical trial registered with www.clinicaltrials.gov (NCT02351141).
引用
- Eddy RL, Svenningsen S, Kirby M, et al. Is Computed Tomography Airway Count Related to Asthma Severity and Airway Structure and Function? Am J Respir Crit Care Med. 2020. PMID: 31895987. doi:10.1164/rccm.201908-1552OC
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。