文献速递间质性肺疾病慢阻肺

揭示肺纤维化合并肺气肿患者劳力性呼吸困难机制

Uncovering the mechanisms of exertional dyspnoea in combined pulmonary fibrosis and emphysema.
PubMed 文献 · Eur Respir J · 2020-01-30

该前瞻性研究对比42例CPFE与16例劳力性低氧血症严重程度匹配的IPF患者,发现CPFE患者运动能力更低但纤维化更轻;劳力性呼吸困难主要与肺气肿区域死腔通气增加导致的通气效率下降有关,而非低氧血症本身。

要点

  • CPFE患者劳力性呼吸困难与高V'E/V'CO2比值相关,而非单纯低氧。
  • V'E/V'CO2最低值>50和总肺气肿范围>15%可预测高呼吸困难负担。
  • 肺气肿严重程度(包括混合型)和牵拉性支气管扩张与通气效率下降相关。

核心结论

  • 低氧血症本身不是CPFE患者劳力性呼吸困难的主要决定因素,肺气肿区域死腔通气增加所致通气效率下降起关键机制作用。

研究设计与样本

  • 前瞻性对照研究,纳入42例CPFE和16例IPF患者,按劳力性低氧血症严重程度匹配;用CT定量肺气肿和肺纤维化,恒功率运动试验评估吸气限制,部分患者获取毛细血管血气。

主要发现

  • CPFE患者运动能力低于IPF(p=0.004)且纤维化范围更小(p=0.02)。
  • 24例CPFE患者以劳力性呼吸困难为主要限制症状,其转移因子、动脉二氧化碳分压和通气效率(更高V'E/V'CO2比值)显著更低。
  • 呼吸困难更重组高死腔/潮气量比、低毛细血管二氧化碳分压、肺气肿严重程度(包括混合型肺气肿)和牵拉性支气管扩张与高V'E/V'CO2比值相关。
  • V'E/V'CO2最低值>50(OR 9.43, 95% CI 5.28-13.6; p=0.0001)和总肺气肿范围>15%(OR 2.25, 95% CI 1.28-3.54; p=0.01)预测CPFE患者高呼吸困难负担伴运动能力严重下降。

关键数值与推荐

  • V'E/V'CO2 nadir >50:OR 9.43, 95% CI 5.28-13.6; p=0.0001。
  • 总肺气肿范围>15%:OR 2.25, 95% CI 1.28-3.54; p=0.01。

临床怎么用

  • CPFE患者劳力性呼吸困难评估应关注通气效率(V'E/V'CO2)和肺气肿范围,而非仅纠正低氧。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The prevailing view is that exertional dyspnoea in patients with combined idiopathic pulmonary fibrosis (IPF) and emphysema (CPFE) can be largely explained by severe hypoxaemia. However, there is little evidence to support these assumptions.We prospectively contrasted the sensory and physiological responses to exercise in 42 CPFE and 16 IPF patients matched by the severity of exertional hypoxaemia. Emphysema and pulmonary fibrosis were quantified using computed tomography. Inspiratory constraints were assessed in a constant work rate test: capillary blood gases were obtained in a subset of patients.CPFE patients had lower exercise capacity despite less extensive fibrosis compared to IPF (p=0.004 and 0.02, respectively). Exertional dyspnoea was the key limiting symptom in 24 CPFE patients who showed significantly lower transfer factor, arterial carbon dioxide tension and ventilatory efficiency (higher minute ventilation (V'E)/carbon dioxide output (V'CO2 ) ratio) compared to those with less dyspnoea. However, there were no between-group differences in the likelihood of pulmonary hypertension by echocardiography (p=0.44). High dead space/tidal volume ratio, low capillary carbon dioxide tension emphysema severity (including admixed emphysema) and traction bronchiectasis were related to a high V'E/V'CO2 ratio in the more dyspnoeic group. V'E/V'CO2 nadir >50 (OR 9.43, 95% CI 5.28-13.6; p=0.0001) and total emphysema extent >15% (2.25, 1.28-3.54; p=0.01) predicted a high dyspnoea burden associated with severely reduced exercise capacity in CPFEContrary to current understanding, hypoxaemia per se is not the main determinant of exertional dyspnoea in CPFE. Poor ventilatory efficiency due to increased "wasted" ventilation in emphysematous areas and hyperventilation holds a key mechanistic role that deserves therapeutic attention.

来源:Eur Respir J,查看原文。版权归原作者所有。

引用

  1. Costa CM, Neder JA, Verrastro CG, et al. Uncovering the mechanisms of exertional dyspnoea in combined pulmonary fibrosis and emphysema. Eur Respir J. 2020. PMID: 31649067. doi:10.1183/13993003.01319-2019