文献速递呼吸危重症与机械通气

低与高CO2清除能力装置实现超保护性通气的疗效与安全性比较:SUPERNOVA研究二次分析

Efficacy and safety of lower versus higher CO2 extraction devices to allow ultraprotective ventilation: secondary analysis of the SUPERNOVA study.
PubMed 文献 · Thorax · 2019-08-13

结果显示高清除能力装置更常达到目标潮气量且不良事件更少。

要点

  • 高CO2清除能力装置更常实现4 mL/kg潮气量且不良事件更少
  • 低清除能力装置ECCO2R相关溶血与出血发生率更高
  • 选择ECCO2R装置时应考虑CO2清除能力以平衡疗效与安全性

核心结论

  • 高CO2清除能力装置更频繁实现4 mL/kg潮气量且不良事件发生率更低。

主要发现

  • 基线后8小时和24小时达到潮气量4 mL/kg的患者比例:低清除能力装置组分别为55%和64%,高清除能力装置组分别为90%和92%(p<0.001)。
  • ECCO2R相关溶血发生率低清除能力装置组为21%,高清除能力装置组为6%(p=0.045)。
  • ECCO2R相关出血发生率低清除能力装置组为27%,高清除能力装置组为6%(p=0.010)。

关键数值与推荐

  • 低清除能力装置:膜面积0.59 m2,血流量300-500 mL/min。
  • 高清除能力装置:膜面积1.30 m2,血流量800-1000 mL/min。

临床怎么用

  • 在ARDS患者中以ECCO2R辅助实现4 mL/kg超保护性通气时,优先选择CO2清除能力较高的装置可能提高达标率并减少溶血与出血。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Retrospective analysis of the SUPERNOVA trial exploring the hypothesis that efficacy and safety of extracorporeal carbon dioxide removal (ECCO2R) to facilitate reduction of tidal volume (VT) to 4 mL/kg in patients with acute respiratory distress syndrome (ARDS) may differ between systems with lower (area of membrane length 0.59 m2; blood flow 300-500 mL/min) and higher (membrane area 1.30 m2; blood flow between 800 and 1000 mL/min) CO2 extraction capacity. Ninety-five patients with moderate ARDS were included (33 patients treated with lower and 62 patients treated with higher CO2 extraction devices). We found that (1) VT of 4 mL/kg was reached by 55% and 64% of patients with the lower extraction versus 90% and 92% of patients with higher extraction devices at 8 and 24 hours from baseline, respectively (p<0.001), and (2) percentage of patients experiencing episodes of ECCO2R-related haemolysis and bleeding was higher with lower than with higher extraction devices (21% vs 6%, p=0.045% and 27% vs 6%, p=0.010, respectively). Although V T of 4 mL/kg could have been obtained with all devices, this was achieved frequently and with a lower rate of adverse events by devices with higher CO2 extraction capacity.

来源:Thorax,查看原文。版权归原作者所有。

引用

  1. Combes A, Tonetti T, Fanelli V, et al. Efficacy and safety of lower versus higher CO2 extraction devices to allow ultraprotective ventilation: secondary analysis of the SUPERNOVA study. Thorax. 2019. PMID: 31409646. doi:10.1136/thoraxjnl-2019-213591

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。