口腔压力传导损害口鼻CPAP治疗OSA的疗效

Transmission of Oral Pressure Compromises Oronasal CPAP Efficacy in the Treatment of OSA.
PubMed 文献 · Chest · 2019-06-22

发现口鼻途径最佳滴定压力更高(P=.005),口腔呼吸>25%者(n=5)无法稳定呼吸;口鼻途径下吸气峰流量更低、驱动压和上气道阻力更高、腭后及舌后面积更小(P<.05),封口贴可消除差异。结论:口腔呼吸及经口压力传导损害口鼻CPAP疗效。

要点

  • 口鼻CPAP最佳滴定压力显著高于鼻CPAP(P=.005)。
  • 口腔呼吸>25%的患者在口鼻CPAP下无法达到稳定呼吸。
  • 封口贴阻断口腔压力传导后可消除口鼻与鼻CPAP的差异。

核心结论

  • 口腔呼吸及经口压力传导会损害口鼻CPAP治疗OSA的疗效。

研究设计与样本

  • 患者在低剂量咪达唑仑下睡眠,使用鼻口腔分隔密封的口鼻面罩,在口鼻与鼻途径间切换CPAP并诱导稳定流限。
  • 另用封口贴阻断口腔压力传导(n=6)。

主要发现

  • 口鼻途径最佳滴定CPAP显著高于鼻途径(P=.005)。
  • 口腔呼吸>25%的患者(n=5)在口鼻CPAP下未能达到稳定呼吸。
  • 稳定流限时,口鼻途径较鼻途径吸气峰流量更低、驱动压更高、上气道吸气阻力更高、腭后和舌后面积更小(所有比较P<.05)。
  • 上述差异在无口腔气流患者中仍存在,封口贴后差异消失(n=6)。

临床怎么用

  • 对口腔呼吸明显的OSA患者,口鼻CPAP可能需要更高压力且疗效可能受限。
  • 封口贴阻断口腔压力传导可能改善口鼻CPAP的疗效。

局限性

  • 患者使用低剂量咪达唑仑睡眠,可能影响生理状态。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: An oronasal mask is frequently used to treat OSA. In contrast to nasal CPAP, the effectiveness of oronasal CPAP varies by unknown mechanisms. We hypothesized that oral breathing and pressure transmission through the mouth compromises oronasal CPAP efficacy. METHODS: Thirteen patients with OSA, well adapted to oronasal CPAP, were monitored by full polysomnography, pharyngeal pressure catheter, and nasoendoscope. Patients slept with low doses of midazolam, using an oronasal mask with sealed nasal and oral compartments. CPAP was titrated during administration by the oronasal and nasal routes, and was then reduced to induce stable flow limitation and abruptly switched to the alternate route. In addition, tape sealing the mouth was used to block pressure transmission to the oral cavity. RESULTS: Best titrated CPAP was significantly higher by the oronasal route rather than the nasal route (P = .005), and patients with > 25% oral breathing (n = 5) failed to achieve stable breathing during oronasal CPAP. During stable flow limitation, inspiratory peak flow was lower, driving pressure was higher, upper airway inspiratory resistance was higher, and retropalatal and retroglossal area were smaller by the oronasal rather than nasal route (P < .05 for all comparisons). Differences were observed even among patients with no oral flow and were abolished when tape sealing the mouth was used (n = 6). CONCLUSIONS: Oral breathing and transmission of positive pressure through the mouth compromise oronasal CPAP.

来源:Chest,查看原文。版权归原作者所有。