文献速递慢阻肺

手持流量计可提高慢阻肺检出率:一项拆分样本验证研究

Handheld flow meter improves COPD detectability regardless of using a conventional questionnaire: A split-sample validation study.
PubMed 文献 · Respirology · 2019-06-12

该研究基于日本Isumi市2008名≥40岁参与者,开发了仅纳入手持流量计评分(sHFM)及联合问卷(IPAG)与流量计评分(sIPAG+HFM)两种慢阻肺检测评分系统,并采用随机拆分样本验证评估预测性能。决策曲线分析显示两种新评分净收益均高于IPAG评分,且特异度显著更高,但两者曲线交叉、敏感度与特异度无显著差异。结论确认手持流量计在慢阻肺筛查中具有显著优势,无论是否使用传统问卷。

要点

  • 手持流量计评分用于慢阻肺筛查可提高检出率,且优于单纯问卷评分。
  • 联合问卷与流量计评分较单纯问卷评分特异度显著提高。
  • 单独流量计评分与联合评分在敏感度和特异度上无显著差异。

核心结论

  • 手持流量计在慢阻肺检测中具有显著优势,无论是否联合使用传统问卷。

研究设计与样本

  • 研究纳入日本Isumi市2008名≥40岁参与者,开发sHFM与sIPAG+HFM两种评分系统。
  • 采用随机拆分样本验证,模型创建集n=1007,模型评估集n=1001。

主要发现

  • 决策曲线分析显示sHFM与sIPAG+HFM的净收益均高于sIPAG。
  • sHFM与sIPAG+HFM的特异度均显著高于sIPAG。
  • sHFM与sIPAG+HFM的曲线交叉,敏感度和特异度无显著差异。

临床怎么用

  • 在慢阻肺筛查中可考虑使用手持流量计评分,以提高检出率并减少对问卷的依赖。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVE: Improved detectability of chronic obstructive pulmonary disease (COPD) using a handheld flow meter (HFM) with symptom-based questionnaires has not been sufficiently evaluated. This study aimed to identify the benefit of using an HFM in COPD screening. METHODS: A total of 2008 participants, who were ≥ 40 years of age, from Isumi City, Japan, were recruited. We developed two novel point systems for detecting COPD, one incorporated score of HFM alone (sHFM) and the other incorporated the score of International Primary Care Airway Group questionnaire (IPAG) and HFM (sIPAG + HFM). Validation using random sample allocation (split-sample validation) was carried out to assess the predictive performance of these models. RESULTS: Participants were assigned to a data set for model creation (n = 1007) or a data set for model assessment (n = 1001) to perform split-sample validation. Decision curve analysis showed that the net benefits of sHFM and sIPAG + HFM were higher than that of the IPAG score (sIPAG) and specificity of the former two were also significantly higher than that of sIPAG. However, the curves of sHFM and sIPAG + HFM were crossing and practically the same with no significant difference in sensitivity and specificity. CONCLUSION: This study confirms that HFM is significantly advantageous in detecting COPD despite the use of a conventional questionnaire.

来源:Respirology,查看原文。版权归原作者所有。

引用

  1. Fujita M, Nagashima K, Takahashi S, et al. Handheld flow meter improves COPD detectability regardless of using a conventional questionnaire: A split-sample validation study. Respirology. 2019. PMID: 31188538. doi:10.1111/resp.13602

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。