高血压合并阻塞性睡眠呼吸暂停患者根据昼夜血压节律对持续气道正压通气治疗的差异化血压反应
该研究为西班牙CEPECTA随机试验的事后分析,纳入272例新发高血压且呼吸暂停低通气指数>15次/小时的阻塞性睡眠呼吸暂停患者,比较CPAP与假CPAP治疗12周对24小时动态血压的影响。结果显示,非杓型患者接受CPAP后24小时和夜间动态血压均降低,而杓型患者无显著变化,组间差异分别为-2.99 mmHg和-5.35 mmHg。
要点
- 非杓型高血压合并OSA患者CPAP治疗12周可降低24小时和夜间动态血压。
- 杓型患者CPAP对动态血压无显著影响,提示血压反应存在昼夜节律依赖性。
- 组间24小时平均动态血压差异为-2.99 mmHg,夜间平均动态血压差异为-5.35 mmHg。
核心结论
- CPAP对高血压合并OSA患者的降压效应因昼夜血压节律而异,仅非杓型患者获得血压下降。
研究设计与样本
- 西班牙CEPECTA多中心随机试验的事后分析,比较CPAP与假CPAP在新发系统性高血压且AHI>15次/小时患者中的效果。
- 纳入基线和干预12周后均有24小时动态血压监测数据的272例高血压患者(杓型113例,非杓型159例)。
主要发现
- 非杓型患者CPAP治疗后24小时动态血压变量和夜间动态血压测量值降低,杓型组无显著效应。
- 组间24小时平均动态血压差异为-2.99 mmHg(95%CI -5.92至-0.06 mmHg)。
- 组间夜间平均动态血压差异为-5.35 mmHg(95%CI -9.01至-1.69 mmHg)。
- 两组基线临床和多导睡眠图变量相似。
关键数值与推荐
- 非杓型患者CPAP治疗12周后24小时平均动态血压组间差异-2.99 mmHg(95%CI -5.92至-0.06 mmHg)。
- 非杓型患者CPAP治疗12周后夜间平均动态血压组间差异-5.35 mmHg(95%CI -9.01至-1.69 mmHg)。
临床怎么用
- 对高血压合并OSA患者,可通过24小时动态血压监测识别非杓型节律,此类患者可能从CPAP治疗中获得降压获益。
局限性
- 本研究为事后分析,结果需在前瞻性研究中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Continuous positive airway pressure (CPAP) has a heterogeneous effect on blood pressure (BP) in hypertensive patients. However, the effect of CPAP on BP in hypertensive subjects regarding circadian BP pattern has never been explored. This study aimed to assess the effect of CPAP on BP, taking into consideration the circadian BP pattern in untreated hypertensive patients.This study is a post hoc analysis of the Spanish Cohort for the Study of the Effect of CPAP in Hypertension (CEPECTA), a multicentre, randomised trial of CPAP versus sham-CPAP in patients with new-onset systemic hypertension and an apnoea-hypopnoea index >15 events·h-1 We included patients for whom 24-h ambulatory BP monitoring (ABPM) data were available at baseline and 12 weeks after the intervention. Subjects were classified based on the dipping ratio (dipper/non-dipper). We evaluated the effect of CPAP on ABPM parameters after 12 weeks of treatment.Overall, 272 hypertensive subjects were included in the analysis (113 dippers and 159 non-dippers). Baseline clinical and polysomnographic variables were similar between the groups. CPAP treatment in non-dipper patients was associated with reductions in 24-h ambulatory BP variables and night-time ambulatory BP measurements. However, a nonsignificant effect was reported in the dipper group. The differential effects of CPAP between the groups were -2.99 mmHg (95% CI -5.92-- -0.06 mmHg) for the mean 24-h ambulatory BP and -5.35 mmHg (95% CI -9.01- -1.69 mmHg) for the mean night-time ambulatory BP.Our results show a differential effect of CPAP treatment on BP in hypertensive patients depending on the circadian pattern. Only non-dipper patients benefited from CPAP treatment in terms of BP reduction.
引用
- Sapiña-Beltrán E, Torres G, Benítez I, et al. Differential blood pressure response to continuous positive airway pressure treatment according to the circadian pattern in hypertensive patients with obstructive sleep apnoea. Eur Respir J. 2019. PMID: 31097515. doi:10.1183/13993003.00098-2019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。