重度哮喘患者递增穿梭步行试验测量特性的解读
该研究纳入50例重度哮喘成人患者,评估递增穿梭步行试验(ISWT)距离的重复性与效度,并与最大递增自行车功率计(ICE)和跑台(ITM)试验的峰值摄氧量(VO2pk)比较。结果显示连续三次ISWT距离均值逐次小幅增加(400、418、438米,P=0.001),ISWT距离与ITM和ICE来源的VO2pk均呈强相关(r=0.74和0.75,P<0.001)。结论提示ISWT有效度但与VO2pk不可互换,临床判断个体真实变化时需考虑重复性系数和异方差性。
要点
- 重度哮喘患者连续三次ISWT距离均值逐次小幅增加,重复性系数和异方差性需纳入个体变化判断。
- ISWT距离与ITM和ICE测得的VO2pk均呈强相关,提示其效度可接受。
- ISWT与VO2pk不可互换,临床解读时应明确测量工具差异。
核心结论
- 连续ISWT测试距离均值有小幅增加,临床评估个体真实变化需考虑重复性系数和异方差性。
- ISWT距离与ICE和ITM测得的VO2pk均有强相关,但两者不可互换。
研究设计与样本
- 研究为重复性与效度评估,纳入50例重度哮喘成人(32例女性,平均年龄54岁,平均FEV1 1.9 L,平均BMI 32 kg/m2),均完成全部五次测试。
- 参与者进行三次ISWT(一次熟悉加两次同日后续测试),并在不同日期以随机顺序完成ICE和ITM至不耐受并分析呼气气体。
主要发现
- 三次ISWT距离均值(标准差)分别为400(156)、418(142)和438(157)米,差异有统计学意义(P=0.001)。
- ISWT距离与ITM来源的VO2pk呈强相关(r=0.74,P<0.001),与ICE来源的VO2pk也呈强相关(r=0.75,P<0.001)。
临床怎么用
- 临床使用ISWT评估重度哮喘患者运动能力时,应结合重复性系数和异方差性判断个体变化是否真实。
- ISWT与VO2pk不可互换,解读结果时应明确所采用的测量工具。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVE: We investigated the repeatability and validity of the incremental shuttle walk test (ISWT) distance compared to peak oxygen uptake (VO2pk ) during maximal incremental cycle ergometer (ICE) and treadmill (ITM) tests in adults with severe asthma. METHODS: Adults with severe asthma, Medical Research Council (MRC) dyspnoea ≥2, were recruited from specialists caring for patients with severe asthma. All participants performed three ISWT (familiarization and two subsequent tests on the same day), an ICE and an ITM in a randomized order, on separate days, to intolerance with expiratory gas analysis. RESULTS: A total of 50 patients (32 females, mean (SD), age: 54 (13) years, forced expiratory volume in 1 s (FEV1 ): 1.9 (0.8) L and body mass index (BMI): 32 (6) kg/m2 ) completed all five tests. The mean (SD) ISWT distance for each test was 400 (156), 418 (142) and 438 (157) m (P = 0.001), respectively. There was a strong correlation between the ISWT distance with VO2pk derived from ITM (r = 0.74, P < 0.001) and ICE (r = 0.75, P < 0.001). CONCLUSION: There was a small increase in the mean ISWT distance on sequential testing. In clinical practice, the coefficient of repeatability and heteroscedasticity need to be considered when assessing whether a true change has occurred within an individual patient. The ISWT has validity compared to VO2pk on both ICE and ITM, but they are not interchangeable.
引用
- Majd S, Hewitt SM, Apps LD, et al. Understanding the measurement properties of the incremental shuttle walk test in patients with severe asthma. Respirology. 2019. PMID: 30887627. doi:10.1111/resp.13519
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。