文献速递间质性肺疾病

特发性肺纤维化中定量CT血管指标的结构-功能研究

Quantitative CT-derived vessel metrics in idiopathic pulmonary fibrosis: A structure-function study.
PubMed 文献 · Respirology · 2019-02-20

本研究纳入152例特发性肺纤维化(IPF)患者,用全自动算法从CT定量血管体积、密度、迂曲度与异质性,其中106例另做动静脉分离定量,并与肺功能指标对照。归一化血管体积与FVC、DLCO、TLC、CPI相关,且与血管异质性独立关联DLCO、TLC和CPI。

要点

  • 归一化血管体积与TLC相关性较强(R²=0.45),与FVC、CPI中等相关。
  • 归一化血管体积与血管异质性独立关联DLCO、TLC和CPI。
  • 动静脉分离未提供超出全血管床的额外信息。

核心结论

  • 新血管定量工具证实IPF中血管体积与功能严重度指标相关,且归一化血管体积与血管异质性独立关联功能指标。
  • 定量血管指标似乎不反映IPF的血管病变性损伤。

研究设计与样本

  • 研究纳入152例IPF患者,用全自动算法从CT图像定量血管体积、密度、迂曲度和异质性。
  • 其中106例另行肺动脉与肺静脉血管指标的分离定量,结果与肺功能测试读数对照。

主要发现

  • 归一化血管体积(占全肺体积百分比)与FVC(R²=0.27,P<1×10⁻⁶)、DLCO(R²=0.12,P=3×10⁻⁵)、TLC(R²=0.45,P<1×10⁻⁶)、CPI(R²=0.28,P<1×10⁻⁶)相关。
  • 归一化血管体积与血管密度相关,但与血管异质性不相关。
  • 定量血管指标及动静脉 subdivision 评分与KCO无显著关联,与DLCO仅弱相关。
  • 多变量线性回归中,归一化血管体积和血管异质性独立关联DLCO、TLC和CPI。
  • 动静脉分离未提供超出全血管床所捕获信息的额外信息。

临床怎么用

  • CT定量血管体积与异质性可作为IPF功能严重度评估的补充影像指标。
  • 动静脉分离定量在IPF中未显示额外价值,可优先采用全血管床指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVE: This study aimed to investigate whether quantitative lung vessel morphology determined by a new fully automated algorithm is associated with functional indices in idiopathic pulmonary fibrosis (IPF). METHODS: A total of 152 IPF patients had vessel volume, density, tortuosity and heterogeneity quantified from computed tomography (CT) images by a fully automated algorithm. Separate quantitation of vessel metrics in pulmonary arteries and veins was performed in 106 patients. Results were evaluated against readouts from lung function tests. RESULTS: Normalized vessel volume expressed as a percentage of total lung volume was moderately correlated with functional indices on univariable linear regression analysis: forced vital capacity (R2 = 0.27, P < 1 × 10-6 ), diffusion capacity for carbon monoxide (DLCO ; R2 = 0.12, P = 3 × 10-5 ), total lung capacity (TLC; R2 = 0.45, P < 1 × 10-6 ) and composite physiologic index (CPI; R2 = 0.28, P < 1 × 10-6 ). Normalized vessel volume was correlated with vessel density but not with vessel heterogeneity. Quantitatively derived vessel metrics (and artery and vein subdivision scores) were not significantly linked with the transfer factor for carbon monoxide (KCO ), and only weakly with DLCO . On multivariable linear regression analysis, normalized vessel volume and vessel heterogeneity were independently linked with DLCO , TLC and CPI indicating that they capture different aspects of lung damage. Artery-vein separation provided no additional information beyond that captured in the whole vasculature. CONCLUSION: Our study confirms previous observations of links between vessel volume and functional measures of disease severity in IPF using a new vessel quantitation tool. Additionally, the new tool shows independent linkages of normalized vessel volume and vessel heterogeneity with functional indices. Quantitative vessel metrics do not appear to reflect vasculopathic damage in IPF.

来源:Respirology,查看原文。版权归原作者所有。

引用

  1. Jacob J, Pienn M, Payer C, et al. Quantitative CT-derived vessel metrics in idiopathic pulmonary fibrosis: A structure-function study. Respirology. 2019. PMID: 30786325. doi:10.1111/resp.13485

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。