文献速递哮喘

FEV1即刻支气管舒张反应作为成人哮喘诊断标准的历史与证据

Immediate bronchodilator response in FEV1 as a diagnostic criterion for adult asthma.
PubMed 文献 · Eur Respir J · 2019-02-14

本文综述了成人哮喘诊断中FEV1支气管舒张反应(ΔFEV1BDR)切阈值的制定历史与证据基础。健康人群绝对ΔFEV1BDR第95百分位为240–320 mL,从初始FEV1计算的相对值为5.9%–13.3%,从预计值计算为8.7%–11.6%;但绝对值和从初始FEV1计算的百分比受年龄、性别、身高和气道阻塞程度影响,从预计FEV1计算可能更合适。目前缺乏足够数据评估各切阈值的敏感性,需在新诊断哮喘患者中进一步研究。

要点

  • 健康人绝对ΔFEV1BDR第95百分位为240–320 mL
  • 从预计FEV1计算的ΔFEV1BDR或更合适
  • 缺乏各切阈值区分哮喘与健康人的敏感性数据

核心结论

  • 健康人群ΔFEV1BDR证据有限,患者研究更少,尚不足以评估各切阈值区分哮喘与健康人的敏感性。
  • 从预计FEV1计算的ΔFEV1BDR可能比从初始FEV1计算更合适。

研究设计与样本

  • 综述纳入与肺量计判读及哮喘诊断相关的主要声明、报告和指南参考文献列表中的研究,并进行了文献检索。
  • 未报告纳入研究的数量或样本量。

主要发现

  • 健康人绝对ΔFEV1BDR第95百分位范围为240 mL至320 mL。
  • 从初始FEV1计算的相对ΔFEV1BDR范围为5.9%至13.3%。
  • 从预计FEV1计算的ΔFEV1BDR范围为8.7%至11.6%。
  • 从初始FEV1计算的绝对和百分比ΔFEV1BDR依赖年龄、性别、身高和气道阻塞程度。

关键数值与推荐

  • ΔFEV1BDR常用诊断值为较基线FEV1增加≥12%且≥200 mL。
  • 健康人绝对ΔFEV1BDR第95百分位为240–320 mL,相对值(初始FEV1)为5.9%–13.3%,相对值(预计FEV1)为8.7%–11.6%。

临床怎么用

  • 解读ΔFEV1BDR时应考虑年龄、性别、身高和气道阻塞程度对绝对值及初始FEV1百分比的影响。
  • 可考虑使用从预计FEV1计算的ΔFEV1BDR辅助判读。
  • 现有切阈值的诊断敏感性证据不足,临床应用需谨慎。

局限性

  • 健康人群ΔFEV1BDR证据有限,患者研究更少。
  • 缺乏足够数据评估任何ΔFEV1BDR切阈值区分哮喘患者与健康人的敏感性。
  • 需在新诊断哮喘患者中开展进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Asthma is characterised by variable and reversible expiratory airflow limitations. Thus, it is logical to use the change in forced expiratory volume in 1 s (FEV1) in response to a bronchodilator (ΔFEV1BDR) as a diagnostic tool; increases of ≥12% and ≥200 mL from the baseline FEV1 are commonly used values. We aimed to evaluate the historical development of diagnostic cut-off levels for the ΔFEV1BDR for adults and the evidence behind these recommendations.We searched for studies from the reference lists of all the main statements, reports and guidelines concerning the interpretation of spirometry and diagnostics for asthma and conducted a literature search.A limited amount of evidence regarding the ΔFEV1BDR in healthy populations was found, and even fewer patient studies were found. In healthy persons, the upper 95th percentile for the absolute ΔFEV1BDR ranges between 240 mL and 320 mL, the relative ΔFEV1BDR calculated from the initial FEV1 ranges from 5.9% to 13.3% and the ΔFEV1BDR calculated from the predicted FEV1 ranges from 8.7% to 11.6%. However, the absolute and percentage ΔFEV1BDR values calculated from the initial FEV1 are dependent on age, sex, height and the degree of airway obstruction. Thus, the use of the ΔFEV1BDR calculated from the predicted FEV1 might be more appropriate.Not enough data exist to assess the sensitivity of any of the cut-off levels for the ΔFEV1BDR to differentiate asthma patients from healthy subjects. Further studies in newly diagnosed asthma patients are needed.

来源:Eur Respir J,查看原文。版权归原作者所有。

引用

  1. Tuomisto LE, Ilmarinen P, Lehtimäki L, et al. Immediate bronchodilator response in FEV1 as a diagnostic criterion for adult asthma. Eur Respir J. 2019. PMID: 30464017. doi:10.1183/13993003.00904-2018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。