虚拟支气管镜导航辅助CT引导经支气管肺活检提高小外周肺病灶诊断率
本研究纳入100例小外周肺病灶(<20 mm)患者,随机分为VBN+组与VBN-组各50例,均行CT引导经支气管肺活检。VBN+组诊断率显著高于VBN-组(84% vs 58%,P=0.013),总检查时间无显著差异,但首次CT扫描及首次活检时间更短,取材标本数更多。
要点
- VBN联合CT-TBB可显著提高<20 mm外周肺病灶的诊断率(84% vs 58%)。
- 联合VBN不延长总检查时间,且首次CT扫描与首次活检时间更短。
- VBN+组取材标本数显著多于VBN-组(3.54±1.07 vs 2.98±1.06,P=0.01)。
核心结论
- VBN联合CT-TBB可显著提高小外周肺病灶的诊断率。
研究设计与样本
- 随机对照研究,纳入100例小外周肺病灶(<20 mm)患者,VBN+组与VBN-组各50例,均行CT-TBB。
主要发现
- VBN+组诊断率为84%,VBN-组为58%,差异有统计学意义(P=0.013)。
- 两组总检查时间无显著差异(VBN+:32分53秒±12分01秒 vs VBN-:33分06秒±10分08秒,P=NS)。
- VBN+组自检查开始至首次CT扫描及首次活检的时间显著更短。
- VBN+组取材标本数显著多于VBN-组(3.54±1.07 vs 2.98±1.06,P=0.01)。
关键数值与推荐
- 小外周肺病灶定义为<20 mm。
- VBN+组诊断率84%,VBN-组58%(P=0.013)。
- VBN+组总检查时间32分53秒±12分01秒,VBN-组33分06秒±10分08秒(P=NS)。
- VBN+组标本数3.54±1.07,VBN-组2.98±1.06(P=0.01)。
临床怎么用
- 对<20 mm外周肺病灶行CT-TBB时,可联合VBN以提高诊断率,且不增加总检查时间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVE: Virtual bronchoscopic navigation (VBN) entails the provision of a virtual display of the bronchial routes that lead to small peripheral pulmonary lesions (PPL). It has been predicted that a combination of computed tomography (CT)-guided transbronchial biopsy (CT-TBB) with VBN might improve the diagnostic yield for small PPL. This study sought to investigate that prediction. METHODS: A total of 100 patients with small PPL (<20 mm) were enrolled for CT-TBB and randomly allocated to either a VBN+ or VBN- group (50 subjects per group). Group results were then compared in terms of diagnostic yield, whole procedure time, times at which the first CT scan and biopsy were taken and the number of lung biopsy specimens retrieved. RESULTS: The diagnostic yield for small PPL was significantly higher in the VBN+ group versus VBN- group (84% vs 58%, respectively (P = 0.013)), with no significant difference in (whole) examination time between groups (VBN+: 32:53 (32 min and 53 s) ± 12:01 vs VBN-: 33:06 ± 10:08 (P = NS)). However, the time periods between commencing the examination and either the first CT scan or first biopsy were significantly shorter for the VBN+ group, while the net biopsy time tended to be longer for this group with a significantly higher number of specimens collected (VBN+: 3.54 ± 1.07 specimens vs VBN-: 2.98 ± 1.06 specimens (P = 0.01)). CONCLUSION: Combining VBN with CT-TBB significantly improved the diagnostic yield for small PPL.
引用
- Kato A, Yasuo M, Tokoro Y, et al. Virtual bronchoscopic navigation as an aid to CT-guided transbronchial biopsy improves the diagnostic yield for small peripheral pulmonary lesions. Respirology. 2018. PMID: 30084517. doi:10.1111/resp.13377
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。