文献速递睡眠呼吸障碍肺栓塞与肺血管病

补充氧气对阻塞性睡眠呼吸暂停患者血压的影响:CPAP撤除随机试验

Effect of Supplemental Oxygen on Blood Pressure in Obstructive Sleep Apnea (SOX). A Randomized Continuous Positive Airway Pressure Withdrawal Trial.
PubMed 文献 · Am J Respir Crit Care Med · 2019-01-01

本研究为随机双盲交叉试验,在中重度OSA患者撤除CPAP 14晚期间比较夜间补充氧气与空气(假干预)对晨间血压的影响。结果显示补充氧气几乎完全消除撤除CPAP后的血压升高,与空气相比显著降低平均收缩压和舒张压升幅,并大幅减少氧减指数,但对AHI和嗜睡无显著影响,提示间歇性缺氧而非反复觉醒是OSA患者日间血压升高的主要原因。

要点

  • 补充氧气几乎完全消除OSA患者撤除CPAP后的晨间血压升高。
  • 与空气相比,氧气显著降低收缩压和舒张压升幅及氧减指数。
  • 氧气对AHI和主观/客观嗜睡无显著影响,提示缺氧主导血压升高。

核心结论

  • 补充氧气几乎完全消除撤除CPAP期间的晨间血压升高。
  • 间歇性缺氧而非反复觉醒似乎是OSA患者日间血压升高的主要原因。

研究设计与样本

  • 随机双盲交叉试验,比较夜间补充氧气与空气(假干预)对晨间血压的影响。
  • 研究对象为中重度OSA患者,在撤除CPAP 14晚期间进行评估。
  • 主要结局为撤除CPAP 14晚后家庭晨间血压变化(氧气 vs 空气)。

主要发现

  • 与空气相比,氧气显著降低平均收缩压升幅(-6.6 mm Hg;95%CI -11.3至-1.9;P=0.008)。
  • 与空气相比,氧气显著降低平均舒张压升幅(-4.6 mm Hg;95%CI -7.8至-1.5;P=0.006)。
  • 与空气相比,氧气显著降低中位氧减指数(-23.8/h;四分位距 -31.0至-16.3;P<0.001)。
  • 氧气与空气在AHI、主观嗜睡和客观嗜睡方面无显著差异。

临床怎么用

  • 对于中重度OSA患者,夜间补充氧气可能有助于减轻撤除CPAP后的晨间血压升高。
  • 补充氧气主要改善间歇性缺氧,对AHI和嗜睡改善有限,不能替代CPAP对呼吸事件的直接治疗。

局限性

  • 研究为撤除CPAP 14晚的短期交叉试验,长期效果未评估。
  • 样本量、纳入人群特征及盲法实施细节在摘要中未完整报告。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

RATIONALE: Obstructive sleep apnea (OSA) is associated with systemic hypertension. Either overnight intermittent hypoxia, or the recurrent arousals that occur in OSA, could cause the daytime increases in blood pressure (BP). OBJECTIVES: To establish the role of intermittent hypoxia in the increased morning BP in patients with OSA. METHODS: Randomized, double-blinded, crossover trial assessing the effects of overnight supplemental oxygen versus air (sham) on morning BP, after continuous positive airway pressure (CPAP) withdrawal in patients with moderate to severe OSA. The primary outcome was the change in home morning BP after CPAP withdrawal for 14 nights, oxygen versus air. Secondary outcomes included oxygen desaturation index (ODI), apnea-hypopnea index (AHI), subjective sleepiness (Epworth Sleepiness Scale score), and objective sleepiness (Oxford Sleep Resistance Test). MEASUREMENTS AND MAIN RESULTS: Supplemental oxygen virtually abolished the BP rise after CPAP withdrawal and, compared with air, significantly reduced the rise in mean systolic BP (-6.6 mm Hg; 95% confidence interval [CI], -11.3 to -1.9; P = 0.008), mean diastolic BP (-4.6 mm Hg; 95% CI, -7.8 to -1.5; P = 0.006), and median ODI (-23.8/h; interquartile range, -31.0 to -16.3; P < 0.001) after CPAP withdrawal. There was no significant difference, oxygen versus air, in AHI, subjective sleepiness, or objective sleepiness. CONCLUSIONS: Supplemental oxygen virtually abolished the rise in morning BP during CPAP withdrawal. Supplemental oxygen substantially reduced intermittent hypoxia, but had a minimal effect on markers of arousal (including AHI), subjective sleepiness, or objective sleepiness. Therefore intermittent hypoxia, and not recurrent arousals, appears to be the dominant cause of daytime increases in BP in OSA.

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

引用

  1. Turnbull CD, Sen D, Kohler M, et al. Effect of Supplemental Oxygen on Blood Pressure in Obstructive Sleep Apnea (SOX). A Randomized Continuous Positive Airway Pressure Withdrawal Trial. Am J Respir Crit Care Med. 2019. PMID: 30025470. doi:10.1164/rccm.201802-0240OC