EBUS-TBNA与手术切除标本PD-L1免疫组化染色比较
PD-L1≥1%时EBUS-TBNA的灵敏度72%、特异度100%、PPV 100%、NPV 80%,一致率87%;PD-L1≥50%时灵敏度47%、特异度93%、PPV 70%、NPV 84%,一致率82%。结论认为≥1%阈值下EBUS-TBNA与切除标本相关性好,但≥50%阈值下灵敏度与PPV明显下降,可能错误分类PD-L1状态。
要点
- EBUS-TBNA标本PD-L1≥1%与手术标本一致率87%,特异度和PPV均为100%。
- PD-L1≥50%时EBUS-TBNA灵敏度仅47%、PPV 70%,一致率82%。
- 以≥50%为阈值时EBUS-TBNA可能错误分类PD-L1状态。
核心结论
- EBUS-TBNA标本PD-L1≥1%与手术切除标本相关性好,但≥50%阈值下灵敏度和PPV明显下降,可能错误分类PD-L1状态。
主要发现
- PD-L1≥1%时EBUS-TBNA的灵敏度72%、特异度100%、PPV 100%、NPV 80%,一致率87%。
- PD-L1≥50%时EBUS-TBNA的灵敏度47%、特异度93%、PPV 70%、NPV 84%,一致率82%。
关键数值与推荐
- PD-L1阳性分别以肿瘤细胞阳性≥1%和≥50%为 cutoff 点。
- PD-L1≥1%一致率87%,PD-L1≥50%一致率82%。
临床怎么用
- EBUS-TBNA标本可用于评估PD-L1≥1%的表达状态。
- 以PD-L1≥50%阈值评估时需谨慎,EBUS-TBNA标本可能错误分类状态。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In advanced non-small cell lung cancer (NSCLC), small biopsy specimens from endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) are often the only available material from cancer tissue for the analysis of programmed death ligand-1 (PD-L1) expression. We aim to assess the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PD-L1 expression at ≥ 1% and ≥ 50% on EBUS-TBNA samples compared with their corresponding surgically resected tumor. METHODS: We retrospectively reviewed all patients who underwent EBUS-TBNA followed by surgical resection of NSCLC between July 2006 and September 2016. Demographic information and periprocedural/surgical data were collected. The archived specimens were retrieved and assessed for PD-L1. A positive PD-L1 stain was defined using two separate cutoff points: ≥ 1% and ≥ 50% of tumor cell positivity. EBUS-TBNA aspirates were compared with the surgically resected specimen to calculate the sensitivity, specificity, PPV, and NPV. RESULTS: Sixty-one patients were included. For PD-L1 ≥ 1%, the sensitivity, specificity, PPV, and NPV were 72%, 100%, 100%, and 80%, respectively. For PD-L1 ≥ 50%, the sensitivity, specificity, PPV, and NPV were 47%, 93%, 70%, and 84%, respectively. The concordance rates for PD-L1 ≥ 1% and ≥ 50% were 87% and 82%, respectively. CONCLUSIONS: A PD-L1 cutoff of ≥ 1% on EBUS-TBNA has a strong correlation with resected tumor specimen. For PD-L1 ≥ 50%, there is a significant decrease in the sensitivity and PPV of EBUS-TBNA specimen when compared with resected tumor. When analyzing for PD-L1 expression using a cutoff of ≥ 50%, EBUS-TBNA specimens may misclassify the status of PD-L1.
引用
- Sakata KK, Midthun DE, Mullon JJ, et al. Comparison of Programmed Death Ligand-1 Immunohistochemical Staining Between Endobronchial Ultrasound Transbronchial Needle Aspiration and Resected Lung Cancer Specimens. Chest. 2018. PMID: 30059678. doi:10.1016/j.chest.2018.07.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。