文献速递哮喘慢阻肺

世贸中心粉尘暴露消防员中哮喘/慢阻肺重叠的预测因素:纵向研究

Predictors of Asthma/COPD Overlap in FDNY Firefighters With World Trade Center Dust Exposure: A Longitudinal Study.
PubMed 文献 · Chest · 2018-07-17

研究纳入2137名世贸中心粉尘暴露的消防员,于2001年至2017年间接受支气管舒张剂肺功能检查。支气管舒张后FEV1增加>12%且200mL定义为哮喘,FEV1/FVC<0.7定义慢阻肺,两者兼有为哮喘/慢阻肺重叠。结果显示血嗜酸性粒细胞≥300 cells/μL与重叠风险升高相关(HR 1.85,95%CI 1.16-2.95),血清IL-4每倍增HR 1.51(95%CI 1.17-1.95)。

要点

  • 血嗜酸性粒细胞≥300 cells/μL与后续哮喘/慢阻肺重叠风险升高相关(HR 1.85)。
  • 血清IL-4每倍增与哮喘/慢阻肺重叠风险升高相关(HR 1.51)。
  • IL-21升高与孤立性哮喘(HR 1.73)和孤立性慢阻肺(HR 2.06)均相关。

核心结论

  • 在世贸中心粉尘暴露的消防员中,血嗜酸性粒细胞和IL-4升高与后续哮喘/慢阻肺重叠诊断相关。

研究设计与样本

  • 纵向研究纳入2137名世贸中心暴露且接受临床指征支气管舒张肺功能检查的消防员,检查时间2001年9月11日至2017年9月10日。
  • 采用边际Cox回归模型分析嗜酸性粒细胞或血清生物标志物与后续诊断的关联,校正年龄、种族、吸烟、世贸中心暴露、首次FEV1/FVC比值和BMI。
  • 亚组215名参与者检测了血清IgE和21种细胞因子。

主要发现

  • 支气管舒张肺功能检查诊断哮喘/慢阻肺重叠99例(4.6%),孤立性哮喘202例(9.5%),孤立性慢阻肺215例(10.1%)。
  • 嗜酸性粒细胞≥300 cells/μL与哮喘/慢阻肺重叠风险升高相关(HR 1.85;95%CI 1.16-2.95),与孤立性哮喘或孤立性慢阻肺无显著关联。
  • 血清IL-4每倍增与哮喘/慢阻肺重叠风险升高相关(HR 1.51;95%CI 1.17-1.95)。
  • IL-21升高与孤立性哮喘(HR 1.73;95%CI 1.27-2.35)和孤立性慢阻肺(HR 2.06;95%CI 1.31-3.23)均相关。

关键数值与推荐

  • 哮喘定义:支气管舒张后FEV1较基线增加>12%且200mL。
  • 慢阻肺定义:支气管舒张后FEV1/FVC比值<0.7。
  • 哮喘/慢阻肺重叠定义:同时满足上述两项标准。

临床怎么用

  • 对刺激性暴露后出现气道疾病的患者,可关注血嗜酸性粒细胞和IL-4等2型炎症标志物以评估哮喘/慢阻肺重叠风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Previously healthy firefighters with World Trade Center (WTC) dust exposure developed airway disease. Risk factors for irritant-associated asthma/COPD overlap are poorly defined. METHODS: This study included 2,137 WTC-exposed firefighters who underwent a clinically indicated bronchodilator pulmonary function test (BD-PFT) between 9/11/2001 and 9/10/2017. A post-BD FEV1 increase of > 12% and 200 mL from baseline defined asthma, and a post-BD FEV1/FVC ratio < 0.7 identified COPD cases. Participants who met both criteria had asthma/COPD overlap. Eosinophil levels were measured on screening blood tests performed shortly after 9/11/2001 and prior to BD-PFT; a subgroup of participants also had serum IgE and 21 cytokines measured (n = 215). Marginal Cox regression models for multiple events assessed the associations of eosinophil levels or serum biomarkers with subsequent diagnosis, with age, race, smoking, WTC exposure, first post-9/11 FEV1/FVC ratio, and BMI included as covariates. RESULTS: BD-PFT diagnosed asthma/COPD overlap in 99 subjects (4.6%), isolated-asthma in 202 (9.5%), and isolated-COPD in 215 (10.1%). Eosinophil concentration ≥ 300 cells/μL was associated with increased risk of asthma/COPD overlap (hazard ratio [HR], 1.85; 95% CI, 1.16-2.95) but not with isolated-asthma or isolated-COPD. Serum IL-4 also predicted asthma/COPD overlap (HR, 1.51 per doubling of cytokine concentration; 95% CI, 1.17-1.95). Greater IL-21 concentration was associated with both isolated-asthma and isolated-COPD (HRs of 1.73 [95% CI, 1.27-2.35] and 2.06 [95% CI, 1.31-3.23], respectively). CONCLUSIONS: In WTC-exposed firefighters, elevated blood eosinophil and IL-4 levels are associated with subsequent asthma/COPD overlap. Disease-specific T-helper cell type 2 biomarkers present years before diagnosis suggest patient-intrinsic predisposition to irritant-associated asthma/COPD overlap.

来源:Chest,查看原文。版权归原作者所有。

引用

  1. Singh A, Liu C, Putman B, et al. Predictors of Asthma/COPD Overlap in FDNY Firefighters With World Trade Center Dust Exposure: A Longitudinal Study. Chest. 2018. PMID: 30028968. doi:10.1016/j.chest.2018.07.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。