四肢肌力减弱与内科患者计划拔管后拔管失败的关系
本研究前瞻性纳入377例机械通气超过24小时并按方案脱机的内科ICU患者,在计划拔管当天用MRC量表评估四肢肌力。拔管失败106例(28.1%),失败者MRC中位分低于成功者(14 vs 16,P=0.024),MRC≤10分与48小时内拔管失败独立相关(校正OR 2.131,95%CI 1.071-4.240,P=0.031)。
要点
- 计划拔管当天MRC评分≤10分与48小时内拔管失败独立相关(校正OR 2.131)。
- 拔管失败患者四肢MRC中位分低于拔管成功者(14 vs 16,P=0.024)。
- 拔管失败率随MRC评分四分位升高而显著下降(趋势P<0.001)。
核心结论
- 计划拔管当天评估的四肢肌力减弱与内科患者拔管后48小时内拔管失败率升高独立相关。
研究设计与样本
- 前瞻性队列研究,连续纳入内科ICU中机械通气超过24小时并按方案脱机的患者377例。
- 在计划拔管当天使用MRC量表评估四肢肌力,采用logistic回归分析其与拔管失败的关联。
主要发现
- 377例中106例(28.1%)发生拔管失败。
- 拔管失败者四肢MRC中位分为14(IQR 12-16),低于无失败者的16(IQR 12-18),P=0.024。
- 拔管失败率随MRC评分四分位升高而显著下降(趋势P<0.001)。
- 多变量分析中MRC评分≤10分与48小时内拔管失败独立相关(校正OR 2.131,95%CI 1.071-4.240,P=0.031)。
关键数值与推荐
- 肌力评估工具为MRC量表,评估时机为计划拔管当天。
- MRC评分≤10分作为与拔管失败独立相关的阈值(校正OR 2.131,95%CI 1.071-4.240,P=0.031)。
临床怎么用
- 对内科ICU计划拔管患者,可在拔管当天用MRC量表评估四肢肌力以辅助识别拔管失败高风险者。
- MRC评分≤10分提示拔管后48小时内失败风险较高,需加强拔管后监测与准备。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVE: Limb muscle weakness is associated with difficult weaning. However, there are limited data on extubation failure. The objective of this cohort study was to evaluate the association between limb muscle weakness according to the Medical Research Council (MRC) scale and extubation failure rates among patients in a medical intensive care unit (ICU). METHODS: All consecutive medical ICU patients who were mechanically ventilated for more than 24 h and who were weaned according to protocol were prospectively registered, and limb muscle weakness was assessed using the MRC scale on the day of planned extubation. Association of limb muscle weakness with extubation failure within 48 h following planned extubation was evaluated with logistic regression analysis. RESULTS: Over the study period, 377 consecutive patients underwent planned extubation through a standardized weaning process. Extubation failure occurred in 106 (28.1%) patients. Median scores on the MRC scale for four limbs were lower in patients with extubation failure (14, interquartile range (IQR) 12-16) than in patients without extubation failure (16, IQR 12-18; P = 0.024). In addition, extubation failure rates decreased significantly with increasing quartiles of MRC scores (P for trend <0.001). In multivariable analysis, MRC scores ≤10 points were independently associated with extubation failure within 48 h (adjusted OR 2.131, 95% CI: 1.071-4.240, P = 0.031). CONCLUSION: Limb muscle weakness assessed on the day of extubation was found to be independently associated with higher extubation failure rates within 48 h following planned extubation in medical patients.
引用
- Jeong BH, Nam J, Ko MG, et al. Impact of limb weakness on extubation failure after planned extubation in medical patients. Respirology. 2018. PMID: 29641839. doi:10.1111/resp.13305
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。