低于ARDSNet方案的呼气末正压与小儿急性呼吸窘迫综合征死亡率升高相关
该多中心回顾性研究纳入1134例小儿急性呼吸窘迫综合征(PARDS)患者,分析实际呼气末正压(PEEP)与ARDSNet推荐的PEEP/FiO2模型之间的差异。结果显示,26.6%的患者使用了低于推荐水平的PEEP,其ICU死亡率更高;调整混杂因素后,低PEEP仍与死亡率升高独立相关(OR 2.05,95%CI 1.32-3.17)。
要点
- 26.6%的PARDS患者PEEP低于ARDSNet推荐水平,其ICU死亡率更高。
- 调整混杂后低PEEP仍与死亡率升高独立相关(OR 2.05,95%CI 1.32-3.17)。
- 倾向性评分调整后结果一致(OR 2.00,95%CI 1.24-3.22)。
核心结论
- PARDS患者使用低于ARDSNet PEEP/FiO2模型推荐的PEEP与更高的ICU死亡率相关。
研究设计与样本
- 多中心回顾性分析,合并4个数据集,纳入1134例未采用正式PEEP/FiO2方案管理的PARDS患者。
主要发现
- 26.6%的患者PEEP低于ARDSNet推荐水平,其死亡率高于PEEP符合或高于推荐者(P < 0.001)。
- 调整低氧血症、正性肌力药、合并症、疾病严重度、呼吸机设置、一氧化氮及数据集后,低PEEP仍独立与死亡率升高相关(OR 2.05,95%CI 1.32-3.17)。
- 倾向性评分协变量调整后结果相似(OR 2.00,95%CI 1.24-3.22)。
临床怎么用
- 在PARDS管理中,应关注PEEP是否达到ARDSNet PEEP/FiO2模型推荐水平,避免PEEP相对FiO2不足。
局限性
- 为回顾性分析,非随机对照,无法完全排除残余混杂。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RATIONALE: The ARDS Network (ARDSNet) used a positive end-expiratory pressure (PEEP)/FiO2 model in many studies. In general, pediatric intensivists use less PEEP and higher FiO2 than this model. OBJECTIVES: To evaluate whether children managed with PEEP lower than recommended by the ARDSNet PEEP/FiO2 model had higher mortality. METHODS: This was a multicenter, retrospective analysis of patients with pediatric acute respiratory distress syndrome (PARDS) managed without a formal PEEP/FiO2 protocol. Four distinct datasets were combined for analysis. We extracted time-matched PEEP/FiO2 values, calculating the difference between PEEP level and the ARDSNet-recommended PEEP level for a given FiO2. We analyzed the median difference over the first 24 hours of PARDS diagnosis against ICU mortality and adjusted for confounding variables, effect modifiers, or factors that may have affected the propensity to use lower PEEP. MEASUREMENTS AND MAIN RESULTS: Of the 1,134 patients with PARDS, 26.6% were managed with lower PEEP relative to the amount of FiO2 recommended by the ARDSNet protocol. Patients managed with lower PEEP experienced higher mortality than those who were managed with PEEP levels in line with or higher than recommended by the protocol (P < 0.001). After adjustment for hypoxemia, inotropes, comorbidities, severity of illness, ventilator settings, nitric oxide, and dataset, PEEP lower than recommended by the protocol remained independently associated with higher mortality (odds ratio, 2.05; 95% confidence interval, 1.32-3.17). Findings were similar after propensity-based covariate adjustment (odds ratio, 2.00; 95% confidence interval, 1.24-3.22). CONCLUSIONS: Patients with PARDS managed with lower PEEP relative to FiO2 than recommended by the ARDSNet model had higher mortality. Clinical trials targeting PEEP management in PARDS are needed.
引用
- Khemani RG, Parvathaneni K, Yehya N, et al. Positive End-Expiratory Pressure Lower Than the ARDS Network Protocol Is Associated with Higher Pediatric Acute Respiratory Distress Syndrome Mortality. Am J Respir Crit Care Med. 2018. PMID: 29373802. doi:10.1164/rccm.201707-1404OC
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。