液体平衡与儿童急性哮喘发作临床结局及血管外肺水相关
该研究在因急性哮喘发作住院的儿童中分析液体过负荷与临床结局的关联,并在匹配回顾性队列和前瞻性观察队列中验证,同时用超声评估血管外肺水。结果显示峰值液体过负荷与住院时间更长、治疗时间更长及补充氧使用风险增加相关,液体正平衡合并高负值吸气期胸膜压时血管外肺水增加且结局更差。
要点
- 儿童急性哮喘发作中,峰值液体过负荷与住院时间、治疗时间延长及补充氧使用风险增加相关。
- 液体正平衡合并高度负值吸气期胸膜压时,血管外肺水增加且临床结局更差。
- 提示临床应关注急性哮喘发作患儿的液体管理,避免液体过负荷。
核心结论
- 儿童急性哮喘发作时液体过负荷与血管外肺水增加及更差临床结局相关。
研究设计与样本
- 回顾性队列分析液体过负荷与临床结局的关联,并在匹配回顾性队列和前瞻性观察队列中验证,最后用超声评估血管外肺水。
主要发现
- 回顾性队列中峰值液体过负荷与住院时间更长、治疗时间更长及补充氧使用风险增加相关(P值<0.001)。
- 验证队列获得相似结果。
- 液体平衡与胸膜压存在强交互作用:液体正平衡合并高度负值吸气期胸膜压与血管外肺水增加征象(P<0.001)、住院时间更长(P=0.01)、治疗时间更长(P=0.03)及补充氧使用风险增加(P=0.02)相关。
临床怎么用
- 对因急性哮喘发作住院的儿童,应关注液体平衡,避免液体过负荷。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RATIONALE: The effects of fluid administration during acute asthma exacerbation are likely unique in this patient population: highly negative inspiratory intrapleural pressure resulting from increased airway resistance may interact with excess fluid administration to favor the accumulation of extravascular lung water, leading to worse clinical outcomes. OBJECTIVES: Investigate how fluid balance influences clinical outcomes in children hospitalized for asthma exacerbation. METHODS: We analyzed the association between fluid overload and clinical outcomes in a retrospective cohort of children admitted to an urban children's hospital with acute asthma exacerbation. These findings were validated in two cohorts: a matched retrospective and a prospective observational cohort. Finally, ultrasound imaging was used to identify extravascular lung water and investigate the physiological basis for the inferential findings. MEASUREMENTS AND MAIN RESULTS: In the retrospective cohort, peak fluid overload [(fluid input - output)/weight] is associated with longer hospital length of stay, longer treatment duration, and increased risk of supplemental oxygen use (P values < 0.001). Similar results were obtained in the validation cohorts. There was a strong interaction between fluid balance and intrapleural pressure: the combination of positive fluid balance and highly negative inspiratory intrapleural pressures is associated with signs of increased extravascular lung water (P < 0.001), longer length of stay (P = 0.01), longer treatment duration (P = 0.03), and increased risk of supplemental oxygen use (P = 0.02). CONCLUSIONS: Excess volume administration leading to fluid overload in children with acute asthma exacerbation is associated with increased extravascular lung water and worse clinical outcomes.
引用
- Kantor DB, Hirshberg EL, McDonald MC, et al. Fluid Balance Is Associated with Clinical Outcomes and Extravascular Lung Water in Children with Acute Asthma Exacerbation. Am J Respir Crit Care Med. 2018. PMID: 29313715. doi:10.1164/rccm.201709-1860OC
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。