电视纵隔镜检查在临床N1非小细胞肺癌纵隔分期中的前瞻性多中心研究
本研究前瞻性纳入PET-CT诊断为cN1的可手术非小细胞肺癌患者,评估电视辅助纵隔镜(VAM)或VAM-淋巴结清扫术(VAMLA)检测N2病变的敏感性。105例患者中26%最终发现N2病变,VAM(LA)敏感性73%,阴性预测值92%,准确率93%。
要点
- cN1患者中26%存在隐匿性N2病变,VAM(LA)敏感性73%
- 阴性预测值92%,准确率93%,96%患者评估至少3站淋巴结
- VAM(LA)可作为cN1患者术前纵隔淋巴结评估的首选技术
核心结论
- VAM(LA)在cN1肺癌中检测纵隔淋巴结病变的敏感性为73%,可作为术前纵隔淋巴结评估的首选技术。
研究设计与样本
- 前瞻性多中心试验,连续纳入PET-CT诊断为cN1的可手术疑似或确诊NSCLC患者,行VAM(LA)进行术前纵隔分期。
主要发现
- 105例cN1患者中26%最终发现N2病变。
- VAM(LA)检测N2病变的敏感性为73%,阴性预测值为92%,准确率为93%。
- VAM(LA)期间评估淋巴结站中位数为4站(IQR 3-5),96%的患者评估了至少3站。
关键数值与推荐
- VAM(LA)检测N2病变的敏感性为73%。
- 阴性预测值为92%,准确率为93%。
- 评估淋巴结站中位数为4站(IQR 3-5),96%患者评估至少3站。
临床怎么用
- 对于PET-CT诊断为cN1的NSCLC患者,推荐行VAM(LA)进行术前纵隔淋巴结评估,因隐匿性N2病变风险约四分之一。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
A quarter of patients with clinical N1 (cN1) non-small cell lung cancer (NSCLC) based on positron emission tomography-computed tomography (PET-CT) imaging have occult mediastinal nodal involvement (N2 disease). In a prospective study, endosonography alone had an unsatisfactory sensitivity (38%) in detecting N2 disease. The current prospective multicentre trial investigated the sensitivity of preoperative mediastinal staging by video-assisted mediastinoscopy (VAM) or VAM-lymphadenectomy (VAMLA).Consecutive patients with operable and resectable (suspected) NSCLC and cN1 after PET-CT imaging underwent VAM(LA). The primary study outcome was sensitivity to detect N2 disease. Secondary endpoints were the prevalence of N2 disease, negative predictive value (NPV) and accuracy of VAM(LA).Out of 105 patients with cN1 on imaging, 26% eventually developed N2 disease. Invasive mediastinal staging with VAM(LA) had a sensitivity of 73% to detect N2 disease. The NPV was 92% and accuracy 93%. Median number of assessed lymph node stations during VAM(LA) was 4 (IQR 3-5), and in 96%, at least three stations were assessed.VAM(LA) has a satisfactory sensitivity of 73% to detect mediastinal nodal disease in cN1 lung cancer, and could be the technique of choice for pre-resection mediastinal lymph node assessment in this patient group with a one in four chance of occult-positive mediastinal nodes after negative PET-CT.
引用
- Decaluwé H, Dooms C, D'Journo XB, et al. Mediastinal staging by videomediastinoscopy in clinical N1 non-small cell lung cancer: a prospective multicentre study. Eur Respir J. 2017. PMID: 29269579. doi:10.1183/13993003.01493-2017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。