文献速递睡眠呼吸障碍

CPAP治疗对阻塞性睡眠呼吸暂停患者血压反应:24小时动态血压监测的预测价值

Blood pressure response to CPAP treatment in subjects with obstructive sleep apnoea: the predictive value of 24-h ambulatory blood pressure monitoring.
PubMed 文献 · Eur Respir J · 2017-10-05

本研究在88例中重度OSA男性患者中,于CPAP治疗6个月前后测量24小时动态血压、炎症因子及儿茶酚胺,发现日间舒张压和去甲肾上腺素降低,但24小时及夜间血压无整体变化;夜间血压正常者CPAP后夜间血压升高,而夜间高血压者24小时血压降低。低夜间心率和杓型血压模式可预测夜间血压升高及新发夜间高血压。

要点

  • CPAP可降低日间舒张压和去甲肾上腺素,但对24小时及夜间血压整体无显著影响。
  • 夜间血压正常者CPAP后夜间血压可能升高,夜间高血压者24小时血压降低。
  • 低夜间心率(<68 bpm)和杓型血压模式与夜间血压升高及新发夜间高血压相关。

核心结论

  • 夜间高血压、昼夜血压节律和夜间心率可能是CPAP治疗血压反应的临床预测因素,支持治疗前使用24小时动态血压监测。

研究设计与样本

  • 研究纳入88例中年肥胖男性重度OSA患者(中位AHI 42 events·h-1),62例完成6个月CPAP治疗,60例纳入分析。
  • 在CPAP治疗前后测量24小时动态血压、C反应蛋白、瘦素、脂联素及24小时尿儿茶酚胺。

主要发现

  • CPAP治疗后日间舒张压降低2 mmHg,去甲肾上腺素降低109.5 nmol·day-1。
  • 24小时血压、夜间血压、多巴胺、肾上腺素、CRP、瘦素及脂联素均无显著变化。
  • 夜间血压正常者CPAP后夜间血压升高4 mmHg,夜间高血压者24小时血压降低3 mmHg。
  • 多变量线性回归显示低夜间心率(<68 bpm)和杓型血压模式与夜间血压升高及新发夜间高血压相关。

关键数值与推荐

  • 夜间血压正常者与CPAP后夜间血压升高(+4 mmHg)相关。
  • 夜间高血压者与CPAP后24小时血压降低(-3 mmHg)相关。
  • 低夜间心率(<68 bpm)和杓型血压模式与夜间血压升高及新发夜间高血压相关。

临床怎么用

  • OSA患者启动CPAP治疗前可考虑行24小时动态血压监测,以识别夜间高血压及昼夜节律异常者。
  • 对夜间血压正常、低夜间心率或杓型血压模式者,CPAP治疗中需关注夜间血压升高风险。

局限性

  • 结果需进一步研究证实。
  • 样本为中年肥胖男性重度OSA患者,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The reduction in blood pressure (BP) with continuous positive airway pressure (CPAP) is modest and highly variable. In this study, we identified the variables that predict BP response to CPAP.24-h ambulatory BP monitoring (ABPM), C-reactive protein (CRP), leptin, adiponectin and 24-h urinary catecholamine were measured before and after 6 months of CPAP in obstructive sleep apnoea (OSA) patients.Overall, 88 middle-aged, obese male patients with severe OSA (median apnoea-hypopnoea index 42 events·h-1) were included; 28.4% had hypertension. 62 patients finished the study, and 60 were analysed. The daytime diastolic BP (-2 mmHg) and norepinephrine (-109.5 nmol·day-1) were reduced after CPAP, but no changes in the 24-h BP, night-time BP, dopamine, epinephrine, CRP, leptin or adiponectin were detected. The nocturnal normotension was associated with an increased night-time-BP (+4 mmHg) after CPAP, whereas nocturnal hypertension was associated with a reduction of 24-h BP (-3 mmHg). A multivariate linear regression model showed differential night-time BP changes after CPAP. Specifically, low night-time heart rate (<68 bpm) and BP dipper profile were associated with increased night-time BP and new diagnosis of nocturnal hypertension.Our results suggest that nocturnal hypertension, circadian BP pattern and night-time heart rate could be clinical predictors of BP response to CPAP and support the usefulness of 24-h ABPM for OSA patients before treatment initiation. These results need to be confirmed in further studies.

来源:Eur Respir J,查看原文。版权归原作者所有。

引用

  1. Castro-Grattoni AL, Torres G, Martínez-Alonso M, et al. Blood pressure response to CPAP treatment in subjects with obstructive sleep apnoea: the predictive value of 24-h ambulatory blood pressure monitoring. Eur Respir J. 2017. PMID: 28982776. doi:10.1183/13993003.00651-2017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。