高循环血管生成素-2水平加重内毒素诱导小鼠肺损伤的肺部炎症但不影响血管渗漏或死亡率
该研究在内毒素诱导急性肺损伤小鼠模型中,通过肝细胞特异性过表达使循环ANGPT2水平升高,观察3至72小时。结果发现高循环ANGPT2显著增加支气管肺泡灌洗液总细胞、中性粒细胞、巨噬细胞及炎症细胞因子,但未改变血管渗漏和死亡率,提示其可能加重肺部炎症而通过多效性作用调节血管反应。
要点
- 高循环ANGPT2加重内毒素诱导的肺部炎症细胞浸润和细胞因子升高。
- 高循环ANGPT2不增加血管渗漏或死亡率,部分渗漏指标反而降低。
- ANGPT2中和适配体部分减少肺泡细胞浸润但加重血管渗漏。
核心结论
- 高循环ANGPT2可加重内毒素诱导的肺部炎症,但可能通过多效性作用精细调节肺损伤时的血管反应。
研究设计与样本
- 研究采用条件性肝细胞特异性过表达ANGPT2的转基因小鼠(ANGPT2OVR)及对照tTA小鼠,在脂多糖诱导急性肺损伤后3至72小时观察。
- 使用适配体抑制剂中和循环ANGPT2,并分析肺转录谱随时间的变化。
主要发现
- LPS后48小时,ANGPT2OVR小鼠支气管肺泡灌洗液总细胞数显著高于对照tTA小鼠。
- LPS后6小时,ANGPT2OVR小鼠支气管肺泡灌洗液中性粒细胞、巨噬细胞及炎症细胞因子显著高于对照tTA小鼠。
- LPS诱导的血管渗漏(支气管肺泡灌洗液总蛋白和肺湿干比)在ANGPT2OVR与对照tTA间无差异,但24至48小时支气管肺泡灌洗液IgM和白蛋白水平在ANGPT2OVR小鼠中降低。
- LPS诱导的死亡率在ANGPT2OVR与对照tTA间无显著差异。
- ANGPT2中和适配体部分减轻肺泡细胞浸润,但加重LPS暴露ANGPT2OVR小鼠的血管渗漏。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Elevated plasma levels of angiopoietin-2 (ANGPT2) have been reported in patients with acute lung injury (ALI); however, it remains unclear whether this increase contributes to, or just marks, the underlying vasculopathic inflammation and leak associated with ALI. Here we investigated the biological consequences of inducing high circulating levels of ANGPT2 in a mouse model of endotoxin-induced ALI. METHODS: Transgenic mice (ANGPT2OVR) with elevated circulating levels of ANGPT2, achieved through conditional hepatocyte-specific overexpression, were examined from 3 to 72 hours following lipopolysaccharide (LPS)-induced ALI. An aptamer-based inhibitor was used to neutralise the effects of circulating ANGPT2 in LPS-exposed ANGPT2OVR mice. RESULTS: Total cells, neutrophils and macrophages, as well as inflammatory cytokines, were significantly higher in bronchoalveolar lavage (BAL) of ANGPT2OVR versus littermate controltTA mice at 48 hours and 6 hours post-LPS, respectively. In contrast, LPS-induced vascular leak, evidenced by total BAL protein levels and lung wet/dry ratio, was unchanged between ANGPT2OVR and controlstTA, while BAL levels of IgM and albumin were decreased in ANGPT2OVR mice between 24 hours and 48 hours suggesting a partial attenuation of vascular leak. There was no significant difference in LPS-induced mortality between ANGPT2OVR and controlstTA. An ANGPT2-neutralising aptamer partially attenuated alveolar cell infiltration while exacerbating vascular leak in LPS-exposed ANGPT2OVR mice, supported by underlying time-dependent changes in the lung transcriptional profiles of multiple genes linked to neutrophil recruitment/adhesion and endothelial integrity. CONCLUSIONS: Our findings suggest that high circulating ANGPT2 potentiates endotoxin-induced lung inflammation but may also exert other pleiotropic effects to help fine-tune the vascular response to lung injury.
引用
- Schlosser K, Taha M, Deng Y, et al. High circulating angiopoietin-2 levels exacerbate pulmonary inflammation but not vascular leak or mortality in endotoxin-induced lung injury in mice. Thorax. 2017. PMID: 28947667. doi:10.1136/thoraxjnl-2017-210413
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。