机械通气致肺损伤中的不良心肺交互作用
该研究在大鼠中复现了Webb和Tierney的经典机械通气肺损伤模型,发现高气道峰压(45/0 cm H2O)导致右室充盈周期性中断、右室扩张和肺水肿,水肿由通透性增加及约40%的静水压升高共同所致。
要点
- 高气道峰压联合零呼气末正压可致右室充盈周期性中断和右室扩张。
- 肺水肿源于微血管通透性增加,并因约40%的静水压升高而加重。
- 高气道峰压加零呼气末正压时左室舒张末压升高,而加10 cm H2O呼气末正压时降低。
核心结论
- 高气道峰压联合零呼气末正压导致右室充盈周期性中断和肺灌注周期性中断,最终引起右室衰竭和扩张。
- 肺水肿由通透性增加所致,并因约40%的静水压升高而加重。
- 肺损伤和急性肺心病可能源于肺微血管损伤,机制尚不明确。
研究设计与样本
- Sprague-Dawley大鼠,体重约400 g,按Webb和Tierney方案机械通气60分钟,气道压力为14/0、30/0、45/10、45/0 cm H2O。
- 附加实验持续20分钟以确保所有动物存活,分别评估通透性(每组n=4)、超声心动图(每组n=4)及右室和左室压力(右室n=5,左室n=4)。
主要发现
- 肺/体重比:45/0 > 45/10 ≈ 30/0 ≈ 14/0,P < 0.05,组织学结果复现原研究。
- 45/0组肺水肿明显且迅速,生存时间小于30分钟。
- 45/0组(而非45/10组)出现微血管通透性增加、前负荷周期性消失和右室进行性扩张。
- 左室舒张末压在45/10组降低,在45/0组升高。
临床怎么用
- 临床机械通气时应避免高气道峰压联合零呼气末正压,以预防右室衰竭和肺水肿。
- 对高气道峰压通气患者需关注右室功能及前负荷周期性变化。
局限性
- 研究为大鼠模型,结果外推至临床需谨慎。
- 肺微血管损伤的具体机制尚不明确。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RATIONALE: In the original 1974 in vivo study of ventilator-induced lung injury, Webb and Tierney reported that high Vt with zero positive end-expiratory pressure caused overwhelming lung injury, subsequently shown by others to be due to lung shear stress. OBJECTIVES: To reproduce the lung injury and edema examined in the Webb and Tierney study and to investigate the underlying mechanism thereof. METHODS: Sprague-Dawley rats weighing approximately 400 g received mechanical ventilation for 60 minutes according to the protocol of Webb and Tierney (airway pressures of 14/0, 30/0, 45/10, 45/0 cm H2O). Additional series of experiments (20 min in duration to ensure all animals survived) were studied to assess permeability (n = 4 per group), echocardiography (n = 4 per group), and right and left ventricular pressure (n = 5 and n = 4 per group, respectively). MEASUREMENTS AND MAIN RESULTS: The original Webb and Tierney results were replicated in terms of lung/body weight ratio (45/0 > 45/10 ≈ 30/0 ≈ 14/0; P < 0.05) and histology. In 45/0, pulmonary edema was overt and rapid, with survival less than 30 minutes. In 45/0 (but not 45/10), there was an increase in microvascular permeability, cyclical abolition of preload, and progressive dilation of the right ventricle. Although left ventricular end-diastolic pressure decreased in 45/10, it increased in 45/0. CONCLUSIONS: In a classic model of ventilator-induced lung injury, high peak pressure (and zero positive end-expiratory pressure) causes respiratory swings (obliteration during inspiration) in right ventricular filling and pulmonary perfusion, ultimately resulting in right ventricular failure and dilation. Pulmonary edema was due to increased permeability, which was augmented by a modest (approximately 40%) increase in hydrostatic pressure. The lung injury and acute cor pulmonale is likely due to pulmonary microvascular injury, the mechanism of which is uncertain, but which may be due to cyclic interruption and exaggeration of pulmonary blood flow.
引用
- Katira BH, Giesinger RE, Engelberts D, et al. Adverse Heart-Lung Interactions in Ventilator-induced Lung Injury. Am J Respir Crit Care Med. 2017. PMID: 28795839. doi:10.1164/rccm.201611-2268OC
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。