文献速递肺结节与肺癌

小周围型肺结节<20mm立体定向放疗前经内镜放置金标的安全性与可行性评估

Assessment of Per-Endoscopic Placement of Fiducial Gold Markers for Small Peripheral Lung Nodules < 20 mm Before Stereotactic Radiation Therapy.
PubMed 文献 · Chest · 2017-08-26

本研究评估经虚拟支气管镜联合径向支气管内超声引导下,对<20mm周围型肺结节经内镜放置金标(FM)的性能与并发症。共纳入54例连续患者,其中34例结节<20mm;结果显示79%病例获得组织学样本并成功放置FM,6例发生迁移,80%病例放疗后3个月CT仍可见FM在位,无并发症报告。

要点

  • R-EBUS引导下经内镜放置金标可单次操作同时完成诊断与标记。
  • 34例<20mm结节中79%获得组织学样本并放置金标。
  • 6例发生金标迁移,放疗后3个月80%病例CT仍可见金标在位。

核心结论

  • 对<20mm周围型肺结节,经R-EBUS引导经内镜放置金标并同时诊断是有效且安全的单次操作。

研究设计与样本

  • 回顾性纳入2010年5月至2015年6月连续54例接受虚拟支气管镜联合R-EBUS引导下放置金标的周围型肺结节患者,其中34例结节<20mm。
  • 经活检取样确认后,不使用透视,用支气管刷将金标植入结节内,记录操作性能与并发症。

主要发现

  • 结节长轴中位直径15mm(9-20mm),短轴中位直径11mm(6-20mm),34例中31例短轴<15mm。
  • 23例(79%)在操作中获得组织学样本并放置金标。
  • 6例发生金标迁移,其中2例发生在操作后数小时内。
  • 放疗后3个月CT显示80%病例金标在位且可见,无并发症报告。

临床怎么用

  • 对<20mm且影像不可追踪的周围型肺结节,可考虑R-EBUS引导下经内镜单次操作完成活检与金标放置。
  • 操作后需关注金标迁移风险,尤其术后数小时内。

局限性

  • 研究为单中心连续病例系列,样本量有限(34例<20mm结节)。
  • 金标迁移及3个月在位率基于部分病例随访,未报告迁移对放疗追踪的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Stereotactic radiotherapy is used to treat peripheral lung cancer in inoperable patients. Placement of fiducial gold markers (FMs) is crucial for tracking small lesions that are not visible on chest radiographs. Our objective was to assess endoscopic FM placement in small peripheral lung nodules (PLNs) that are not trackable using automated tracking software. METHODS: All patients benefiting from virtual bronchoscopy and radial endobronchial ultrasonography (R-EBUS)-guided placement of FMs for PLNs < 20 mm were included. After confirmation by biopsy sampling, a gold-seed FM was inserted into the nodule using a bronchial brush, without the use of fluoroscopy. The performance and complications of the procedure were recorded. RESULTS: From May 2010 to June 2015, FMs were placed in the PLNs of 54 consecutive patients, 34 of whom presented with a nodule < 20 mm. Seventy-six percent of the procedures were performed using local anesthesia on an outpatient basis. The median long- and short-axis diameters of nodules were 15 mm (9-20 mm) and 11 mm (6-20 mm), respectively, with 31 of 34 nodules exhibiting a short axis of < 15 mm. In 23 cases (79%), histologic samples were obtained during the procedure that allowed FM placement. Migration occurred in six cases, including two in the hours following the procedure. FMs were in place and visible on CT imaging performed 3 months after radiation therapy in 80% of cases. No complications were reported. CONCLUSIONS: Diagnosis of peripheral nodules < 20 mm and FM placement using R-EBUS are efficient and safe in a single procedure.

来源:Chest,查看原文。版权归原作者所有。

引用

  1. Lachkar S, Guisier F, Roger M, et al. Assessment of Per-Endoscopic Placement of Fiducial Gold Markers for Small Peripheral Lung Nodules < 20 mm Before Stereotactic Radiation Therapy. Chest. 2017. PMID: 28847547. doi:10.1016/j.chest.2017.08.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。