气道口径变化是呼出气一氧化氮反映哮喘控制能力的主要决定因素
该研究在527例哮喘患者中评估FEV1变化是否影响FENO反映哮喘控制的能力。结果显示当FEV1与FENO同向变化时,FENO与ACQ不一致的比值增加3倍(p<0.001);两者反向变化时FENO识别哮喘控制改善或恶化的AUC分别为0.765和0.769,而同向变化时AUC仅0.590和0.498。
要点
- FEV1与FENO同向变化时,FENO与ACQ不一致的比值增加3倍。
- FEV1与FENO反向变化时,FENO识别哮喘控制变化的AUC为0.765和0.769。
- FEV1与FENO同向变化时,FENO识别哮喘控制变化的AUC仅0.590和0.498。
核心结论
- FEV1与FENO concomitant变化的方向决定FENO捕捉哮喘控制变化的能力:平行变化降低该能力,反向变化提高该能力。
研究设计与样本
- 在527例患者中至少两次测量FENO、ACQ和FEV1,共1819对访视。
- 通过logistic回归分析FENO-ACQ不一致概率的决定因素。
- 采用分层ROC曲线分析评估FENO捕捉哮喘控制恶化或改善的效果。
主要发现
- 当FEV1和FENO同向变化时,FENO-ACQ不一致的比值增加3倍(p<0.001)。
- FEV1和FENO反向变化时,FENO识别哮喘控制改善的AUC为0.765(95% CI 0.713-0.805,p<0.001),识别恶化的AUC为0.769(95% CI 0.706-0.810,p<0.001)。
- FEV1和FENO同向变化时,FENO识别哮喘控制改善的AUC为0.590(95% CI 0.531-0.653,p=0.001),识别恶化的AUC为0.498(95% CI 0.416-0.567,p=0.482)。
临床怎么用
- 解读FENO与哮喘控制的关系时需考虑同期FEV1变化方向,同向变化时FENO可靠性下降。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Changes in airway calibre have the potential to modify exhaled nitric oxide fraction (FENO) values and could hamper how FENO captures changes in asthma control. Here, our objective was to assess whether forced expiratory volume in 1 s (FEV1) variations alter the ability of FENO to reflect asthma control.FENO, asthma control (Asthma Control Questionnaire (ACQ)) and FEV1 were measured at least two times in 527 patients during 1819 pairs of visits. Determinants of FENO-ACQ discordance probability were evaluated through a logistic regression analysis. The effectiveness of FENO at capturing either asthma control worsening or improvement between two visits was then assessed by undertaking a stratified receiver operating characteristic curves analysis.When FEV1 and FENO change in the same direction, the odds of FENO-ACQ being discordant are multiplied by 3 (p<0.001). The area under the curve values were 0.765 (95% CI 0.713-0.805) (improvement; p<0.001) and 0.769 (95% 0.706-0.810) (worsening; p<0.001) or 0.590 (95% 0.531-0.653) (improvement; p=0.001) and 0.498 (95% 0.416-0.567) (worsening; p=0.482) when FEV1 and FENO changed in the opposite or same direction, respectively.The manner in which FENO and FEV1 vary concomitantly when asthma control changes determines the ability of FENO to capture this change: parallel or opposite changes in FEV1 and FENO either decrease or increase this ability to capture asthma control changes.
引用
- Michils A, Haccuria A, Michiels S, et al. Airway calibre variation is a major determinant of exhaled nitric oxide's ability to capture asthma control. Eur Respir J. 2017. PMID: 28818874. doi:10.1183/13993003.00392-2017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。