文献速递肺结节与肺癌

电磁导航支气管镜中呼气相与吸气相虚拟气道图预测肺结节位置的比较

Comparing Pulmonary Nodule Location During Electromagnetic Bronchoscopy With Predicted Location on the Basis of Two Virtual Airway Maps at Different Phases of Respiration.
PubMed 文献 · Chest · 2017-06-16

本研究纳入连续需组织学诊断的肺结节患者,术前分别获取吸气相和呼气相CT构建两套虚拟气道图,在电磁导航支气管镜操作中通过管腔配准收集实际三维点。结果显示呼气相图预测结节位置与管腔配准的距离显著小于吸气相图(4.5 mm ± 3.3 mm vs 14.8 mm ± 9.7 mm,p < 0.0001)。

要点

  • 呼气相CT构建的虚拟图预测肺结节位置比吸气相图更接近实际管腔配准位置。
  • 呼气相与吸气相预测误差分别为4.5 mm ± 3.3 mm和14.8 mm ± 9.7 mm,差异显著。
  • 该改进是否提高电磁导航支气管镜的诊断率尚需进一步研究确定。

核心结论

  • 使用呼气相CT预测的肺结节三维位置比吸气相CT更接近电磁导航支气管镜中的实际结节位置。
  • 这一位置准确性的提升能否转化为更高的诊断率仍需确定。

研究设计与样本

  • 连续纳入需要组织学诊断的肺结节患者。
  • 术前分别进行吸气相和呼气相CT扫描以构建两套虚拟气道图。
  • 在气道检查过程中系统追踪传感器探头收集三维点并重建管腔配准图。
  • 比较呼气相和吸气相虚拟图上预测的肺结节位置与管腔配准图的距离。

主要发现

  • 呼气相图预测结节位置与管腔配准的距离为4.5 mm ± 3.3 mm。
  • 吸气相图预测结节位置与管腔配准的距离为14.8 mm ± 9.7 mm。
  • 呼气相与吸气相预测距离差异具有统计学意义(p < 0.0001)。

临床怎么用

  • 在电磁导航支气管镜术前规划中,可考虑采用呼气相CT构建虚拟气道图以更准确预测肺结节位置。
  • 需注意目前证据仅显示位置预测更准确,尚未证实能提高诊断率。

局限性

  • 研究未评估位置准确性提升是否转化为诊断率的提高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Electromagnetic navigational bronchoscopy (ENB) is guided bronchoscopy to pulmonary nodules (PN) that relies on a preprocedural chest CT to create a three-dimensional (3D) virtual airway map. The CT is traditionally done at a full inspiratory breath hold (INSP), but the procedure is performed while the patient tidal breaths, when lung volumes are closer to functional residual capacity. Movement of a PN from INSP to expiration (EXP) has been shown to average 17.6 mm. Therefore, the hypothesis of this study is that preprocedural virtual maps built off a CT closer to physiological lung volumes during bronchoscopy may better represent the actual 3D location of a PN. METHODS: Consecutive patients with a PN needing a histological diagnosis were enrolled. A preprocedure INSP and EXP CT scan were obtained to create two virtual maps. During the airway inspection, the system tracked the sensor probe to collect 3D points that were reconstructed into the lumen registration map. This map is thought to best represent the patient's airways during bronchoscopy. Predicted PN location on an EXP and INSP map was compared with lumen registration. RESULTS: Twenty consecutive PN underwent ENB. The predicted PN location, compared with lumen registration, was significantly closer on EXP vs INSP (4.5 mm ± 3.3 mm vs 14.8 mm ± 9.7 mm; p < 0.0001). CONCLUSIONS: Predicted 3D nodule location using an EXP scan for ENB is significantly closer to actual nodule location when compared with an INSP scan, but whether this leads to increased yields needs to be determined.

来源:Chest,查看原文。版权归原作者所有。

引用

  1. Furukawa BS, Pastis NJ, Tanner NT, et al. Comparing Pulmonary Nodule Location During Electromagnetic Bronchoscopy With Predicted Location on the Basis of Two Virtual Airway Maps at Different Phases of Respiration. Chest. 2017. PMID: 28629919. doi:10.1016/j.chest.2017.06.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。