文献速递呼吸危重症与机械通气

电阻抗断层成像辅助ECMO治疗的重度ARDS患者床旁PEEP设定

Bedside Contribution of Electrical Impedance Tomography to Setting Positive End-Expiratory Pressure for Extracorporeal Membrane Oxygenation-treated Patients with Severe Acute Respiratory Distress Syndrome.
PubMed 文献 · Am J Respir Crit Care Med · 2017-01-01

本研究在15例接受ECMO和低潮气量机械通气的重度ARDS患者中,用电阻抗断层成像(EIT)监测递减PEEP试验(20-0 cm H2O,每步5 cm H2O),以EIT评估的塌陷≤15%且过度膨胀最少定义最佳妥协PEEP。结果显示最佳妥协PEEP在15、10、5 cm H2O分别为7、6、2例,PEEP20和PEEP0从未被选,提示最佳PEEP个体差异大,EIT可用于床旁实时监测PEEP影响。

要点

  • EIT可床旁监测递减PEEP试验,帮助确定重度ARDS患者的最佳妥协PEEP。
  • 本组15例ECMO患者最佳妥协PEEP分布为15、10、5 cm H2O,个体差异大。
  • EIT可能为ECMO下重度ARDS患者的无创PEEP滴定工具。

核心结论

  • ECMO治疗的重度ARDS患者最佳PEEP个体差异大,EIT可作为无创床旁工具实时监测PEEP影响。

研究设计与样本

  • 对15例接受ECMO和机械通气的重度ARDS患者进行递减PEEP试验(20-0 cm H2O,每步5 cm H2O),用EIT监测并将肺图像分为四个腹背侧水平感兴趣区。

主要发现

  • 潮气量为2.9-4 ml/kg理想体重,静态顺应性为12.1-18.7 ml/cm H2O,PEEP10和PEEP5时潮气量和顺应性显著高于PEEP20。
  • EIT确定的最佳妥协PEEP在15、10、5 cm H2O分别为7、6、2例,PEEP20和PEEP0从未被选。

关键数值与推荐

  • EIT最佳妥协PEEP定义为将EIT评估的塌陷限制在≤15%且过度膨胀最低的最低压力,驱动压恒定在14 cm H2O(压力控制模式)。

临床怎么用

  • 对ECMO治疗的重度ARDS患者,可考虑用EIT床旁监测递减PEEP试验以个体化设定PEEP。

局限性

  • 样本量仅15例,最佳妥协PEEP定义为任意设定,需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

RATIONALE: Optimal positive end-expiratory pressure (PEEP) is unknown in patients with severe acute respiratory distress syndrome (ARDS) on extracorporeal membrane oxygenation receiving mechanical ventilation with very low tidal volume. OBJECTIVES: To evaluate the ability of electrical impedance tomography (EIT) to monitor a PEEP trial and to derive from EIT the best compromise PEEP in this setting. METHODS: A decremental PEEP trial (20-0 cm H2O) in 5 cm H2O steps was monitored by EIT, with lung images divided into four ventral-to-dorsal horizontal regions of interest. The EIT-based PEEP providing the best compromise between overdistention and collapsed zones was arbitrarily defined as the lowest pressure able to limit EIT-assessed collapse to less than or equal to 15% with the least overdistention. Driving pressure was maintained constant at 14 cm H2O in pressure controlled mode. MEASUREMENTS AND MAIN RESULTS: Tidal volume, static compliance, tidal impedance variation, end-expiratory lung impedance, and their respective regional distributions were visualized at each PEEP level in 15 patients on extracorporeal membrane oxygenation. Low tidal volume (2.9-4 ml/kg ideal body weight) and poor compliance (12.1-18.7 ml/cm H2O) were noted, with significantly higher tidal volume and compliance at PEEP10 and PEEP5 than PEEP20. EIT-based best compromise PEEPs were 15, 10, and 5 cm H2O for seven, six, and two patients, respectively, whereas PEEP20 and PEEP0 were never selected. CONCLUSIONS: The broad variability in optimal PEEP observed in these patients with severe ARDS under extracorporeal membrane oxygenation reinforces the need for personalized titration of ventilation settings. EIT may be an interesting noninvasive bedside tool to provide real-time monitoring of the PEEP impact in these patients.

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

引用

  1. Franchineau G, Bréchot N, Lebreton G, et al. Bedside Contribution of Electrical Impedance Tomography to Setting Positive End-Expiratory Pressure for Extracorporeal Membrane Oxygenation-treated Patients with Severe Acute Respiratory Distress Syndrome. Am J Respir Crit Care Med. 2017. PMID: 28103448. doi:10.1164/rccm.201605-1055OC

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。