文献速递呼吸道感染呼吸危重症与机械通气

机械通气期间肺部微生物组的动态变化及其与肺炎发生的关联

The dynamics of the pulmonary microbiome during mechanical ventilation in the intensive care unit and the association with occurrence of pneumonia.
PubMed 文献 · Thorax · 2017-01-18

该研究纳入35例ICU机械通气患者,每周3次采集气管吸引物,共111份标本,采用16S rRNA基因测序分析呼吸道微生物组组成。结果显示,机械通气时长与α多样性下降相关(Shannon指数固定效应β:-0.03,95%CI -0.05至-0.005),而抗生素使用未见此关联;发生呼吸机相关性肺炎(VAP)的患者β多样性的变化显著大于对照组。

要点

  • 机械通气时间越长,呼吸道微生物α多样性越低。
  • 抗生素使用与微生物组多样性变化无显著关联。
  • 发生VAP的患者微生物群落失衡更明显。

核心结论

  • 机械通气(而非抗生素使用)与呼吸道微生物组变化相关。
  • 发生VAP的患者呼吸道微生物群落失衡最为显著。

研究设计与样本

  • 研究纳入插管并接受机械通气的ICU患者,每周采集3次气管吸引物。
  • 采用Roche 454平台的16S rRNA基因测序测定呼吸道微生物组组成。
  • 共从35例患者获得111份气管吸引物,其中11例发生VAP,18例未发生VAP,另有6例在插管后48小时内发生肺炎。
  • 关联分析采用线性混合模型分析和主坐标分析。

主要发现

  • 机械通气时长与α多样性下降相关(Shannon指数;固定效应回归系数β:-0.03,95%CI -0.05至-0.005)。
  • 抗生素治疗与α多样性变化无显著关联(固定效应β:0.06,95%CI -0.17至0.30)。
  • 发生VAP的患者与对照患者之间β多样性的变化存在显著差异(Bray-Curtis距离p=0.03,Manhattan距离p=0.04)。
  • Burkholderia、Bacillales及程度较轻的Pseudomonadales与β多样性的变化呈正相关。

临床怎么用

  • 对机械通气患者应关注呼吸道微生物组失衡,通气时间延长可能增加菌群多样性下降。
  • VAP发生时微生物群落失衡更明显,提示微生物组监测可能有助于识别VAP高风险患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

RATIONALE: Ventilator-associated pneumonia (VAP) is the most common nosocomial infections in patients admitted to the ICU. The adapted island model predicts several changes in the respiratory microbiome during intubation and mechanical ventilation. OBJECTIVES: We hypothesised that mechanical ventilation and antibiotic administration decrease the diversity of the respiratory microbiome and that these changes are more profound in patients who develop VAP. METHODS: Intubated and mechanically ventilated ICU-patients were included. Tracheal aspirates were obtained three times a week. 16S rRNA gene sequencing with the Roche 454 platform was used to measure the composition of the respiratory microbiome. Associations were tested with linear mixed model analysis and principal coordinate analysis. MEASUREMENTS AND MAIN RESULTS: 111 tracheal aspirates were obtained from 35 patients; 11 had VAP, 18 did not have VAP. Six additional patients developed pneumonia within the first 48 hours after intubation. Duration of mechanical ventilation was associated with a decrease in α diversity (Shannon index; fixed-effect regression coefficient (β): -0.03 (95% CI -0.05 to -0.005)), but the administration of antibiotic therapy was not (fixed-effect β: 0.06; 95% CI -0.17 to 0.30). There was a significant difference in change of β diversity between patients who developed VAP and control patients for Bray-Curtis distances (p=0.03) and for Manhattan distances (p=0.04). Burkholderia, Bacillales and, to a lesser extent, Pseudomonadales positively correlated with the change in β diversity. CONCLUSION: Mechanical ventilation, but not antibiotic administration, was associated with changes in the respiratory microbiome. Dysbiosis of microbial communities in the respiratory tract was most profound in patients who developed VAP.

来源:Thorax,查看原文。版权归原作者所有。

引用

  1. Zakharkina T, Martin-Loeches I, Matamoros S, et al. The dynamics of the pulmonary microbiome during mechanical ventilation in the intensive care unit and the association with occurrence of pneumonia. Thorax. 2017. PMID: 28100714. doi:10.1136/thoraxjnl-2016-209158

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。