OSA共存可能补偿COPD患者睡眠相关神经呼吸驱动下降
该研究比较了单纯COPD与重叠综合征(COPD+OSA)患者在2期睡眠时的膈肌肌电(EMGdi)和通气,发现单纯COPD睡眠低通气源于神经呼吸驱动下降,而重叠综合征则源于上气道阻力增加。
要点
- 单纯COPD患者2期睡眠时神经呼吸驱动(EMGdi)显著下降,导致低通气。
- 重叠综合征患者睡眠时神经呼吸驱动变化不大,低通气由上气道阻力增加所致。
- COPD与OSA共存可能通过维持神经驱动来补偿睡眠相关驱动下降。
核心结论
- 单纯COPD的2期睡眠低通气由神经呼吸驱动下降引起,重叠综合征则由上气道阻力增加引起。
研究设计与样本
- 前瞻性观察研究,纳入14名健康受试者、14例OSA患者和39例连续COPD患者,进行完整多导睡眠监测记录EMGdi和气流。
- 最终完成研究:35例COPD患者(其中19例单纯COPD,16例重叠综合征)、12名健康受试者和14例OSA患者。
- 测量潮气量与EMGdi比值以间接评估上气道阻力。
主要发现
- 单纯COPD患者2期睡眠通气从清醒时8.6±2.0 L/min降至6.5±1.5 L/min(p<0.001),重叠综合征从8.3±2.0 L/min降至6.1±1.8 L/min。
- 单纯COPD患者神经呼吸驱动从清醒时29.5±13.3%最大值降至睡眠时23.0±8.9%(p<0.01),重叠综合征变化很小。
- 潮气量/EMGdi比值在单纯COPD和健康受试者清醒至睡眠无变化,但在OSA或重叠综合征患者显著降低(p<0.05)。
临床怎么用
- 对于COPD患者,应评估是否共存OSA,因重叠综合征的睡眠低通气机制不同。
- 重叠综合征患者睡眠低通气主要与上气道阻力增加有关,可能需针对OSA治疗。
局限性
- 样本量有限,COPD患者39例中仅35例完成研究。
- 仅评估2期睡眠,未涵盖其他睡眠阶段。
- 未明确报告随机化或盲法设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The mechanisms underlying sleep-related hypoventilation in patients with coexisting COPD and obstructive sleep apnoea (OSA), an overlap syndrome, are incompletely understood. We compared neural respiratory drive expressed as diaphragm electromyogram (EMGdi) and ventilation during stage 2 sleep in patients with COPD alone and patients with overlap syndrome. METHODS: EMGdi and airflow were recorded during full polysomnography in 14 healthy subjects, 14 patients with OSA and 39 consecutive patients with COPD. The ratio of tidal volume to EMGdi was measured to indirectly assess upper airway resistance. RESULTS: Thirty-five patients with COPD, 12 healthy subjects and 14 patients with OSA completed the study. Of 35 patients with COPD, 19 had COPD alone (FEV1 38.5%±16.3%) whereas 16 had an overlap syndrome (FEV1 47.5±16.2%, AHI 20.5±14.1 events/hour). Ventilation (VE) was lower during stage 2 sleep than wakefulness in both patients with COPD alone (8.6±2.0 to 6.5±1.5 L/min, p<0.001) and those with overlap syndrome (8.3±2.0 to 6.1±1.8 L/min). Neural respiratory drive from wakefulness to sleep decreased significantly for patients with COPD alone (29.5±13.3% to 23.0±8.9% of maximal, p<0.01) but it changed little in those with overlap syndrome. The ratio of tidal volume to EMGdi was unchanged from wakefulness to sleep in patients with COPD alone and healthy subjects but was significantly reduced in patients with OSA or overlap syndrome (p<0.05). CONCLUSIONS: Stage 2 sleep-related hypoventilation in COPD alone is due to reduction of neural respiratory drive, but in overlap syndrome it is due to increased upper airway resistance.
引用
- He BT, Lu G, Xiao SC, et al. Coexistence of OSA may compensate for sleep related reduction in neural respiratory drive in patients with COPD. Thorax. 2016. PMID: 27807016. doi:10.1136/thoraxjnl-2016-208467
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。