COPD评估测试在特发性肺纤维化患者健康状况测量中的横断面研究
本研究纳入106例新诊断特发性肺纤维化(IPF)患者,评估COPD评估测试(CAT)测量健康状况的效度。CAT与圣乔治呼吸问卷(SGRQ)总分显著相关(r=0.72,P<0.001),内部一致性(Cronbach's α=0.869)和3个月重测信度(组内相关系数=0.742)均显著。结论认为CAT是IPF患者有效的健康状况测量工具。
要点
- CAT与SGRQ总分显著相关(r=0.72,P<0.001),在IPF中具有效度。
- CAT内部一致性Cronbach's α=0.869,3个月重测信度ICC=0.742。
- mMRC、静息PaO2、6MWT最低SpO2和HADS焦虑是CAT的独立预测因子。
核心结论
- CAT是IPF患者有效的健康状况测量工具。
- 多元回归显示CAT与呼吸困难严重程度、氧合损害和焦虑显著相关。
研究设计与样本
- 横断面研究,纳入106例连续新诊断IPF患者。
- 完成肺功能、静息动脉血氧分压(PaO2)、6分钟步行试验(6MWT)、CAT、SGRQ、mMRC呼吸困难和医院焦虑抑郁量表(HADS)评估。
主要发现
- 受试者肺功能显示轻至中度限制性通气功能障碍。
- CAT平均得分12.8±8.0,SGRQ总分平均30.8±17.7。
- CAT与SGRQ总分同时效度显著(r=0.72,P<0.001)。
- CAT内部一致性Cronbach's α=0.869,3个月重测信度组内相关系数=0.742。
- 多元回归中mMRC、静息PaO2、6MWT最低SpO2和HADS焦虑为CAT独立预测因子。
关键数值与推荐
- CAT与SGRQ总分相关系数r=0.72(P<0.001)。
- Cronbach's α=0.869;重测组内相关系数=0.742。
临床怎么用
- CAT可用于IPF患者健康状况评估,尤其适用于关注呼吸困难、氧合和焦虑对健康状态影响的场景。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVE: The COPD Assessment Test (CAT) has been reported to have potential utility for measuring health status of idiopathic pulmonary fibrosis (IPF). Although the CAT has been developed for the assessment of COPD patients, it has not been fully evaluated exclusively in IPF. This study was designed to evaluate the validity of the CAT in IPF. METHODS: The clinical data for 106 consecutive subjects with newly diagnosed IPF who completed pulmonary function tests, partial pressure of oxygen in arterial blood (PaO2 ) at rest, 6-min walk test (6MWT), CAT, St George's Respiratory Questionnaire (SGRQ), modified Medical Research Council (mMRC) dyspnoea grade and Hospital Anxiety and Depression Scale (HADS), were analysed. We assessed the validity of the CAT in comparison with the SGRQ. RESULTS: The present subjects showed mild to moderate restrictive impairment on spirometry. Mean CAT score and total SGRQ were 12.8 ± 8.0 and 30.8 ± 17.7, respectively. The concurrent validity of the CAT score in comparison with the SGRQ total score was significant (r = 0.72, P < 0.001). Internal consistency (Cronbach's α = 0.869) and repeatability over 3 months (intraclass correlation coefficient = 0.742) of the CAT were also significant. Single regression analysis showed that the CAT had significant construct validity. In multiple regression analysis, mMRC, PaO2 at rest, minimum SpO2 during 6MWT and anxiety of HADS were independent predictors for the CAT. CONCLUSIONS: The CAT is a valid health status measurement in IPF patients. Multiple regression analysis showed that the CAT was significantly correlated with dyspnoea severity, oxygenation impairment and anxiety.
引用
- Matsuda T, Taniguchi H, Ando M, et al. COPD Assessment Test for measurement of health status in patients with idiopathic pulmonary fibrosis: A cross-sectional study. Respirology. 2016. PMID: 27859913. doi:10.1111/resp.12936
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。