经治疗型支气管镜3.0mm工作通道直接回收1.1mm冷冻探头活检标本的安全性与有效性:多中心前瞻性观察研究
本研究为多中心前瞻性观察研究,纳入100例疑似肺癌的周围型肺病变患者,评估经治疗型支气管镜3.0mm工作通道使用1.1mm冷冻探头直接回收标本的安全性与有效性。主要终点为出血分级,结果显示严重出血(Grade 3)发生率为2.1%,冷冻活检诊断率为79.1%,联合钳夹活检总诊断率为87.5%,且冷冻标本面积显著大于钳夹活检。
要点
- 经3.0mm工作通道直接回收1.1mm冷冻探头标本技术可行,严重出血风险低。
- 冷冻活检联合钳夹活检总诊断率达87.5%,冷冻活检可提供补充诊断价值。
- 冷冻活检标本面积显著大于钳夹活检,且多重基因检测成功率高。
核心结论
- 经治疗型支气管镜工作通道直接回收1.1mm冷冻探头活检标本安全可行,标本更大且具有补充诊断价值。
研究设计与样本
- 多中心前瞻性观察研究,纳入100例疑似肺癌的周围型肺病变患者,96例纳入分析,84例接受冷冻活检。
主要发现
- 出血分级:Grade 0占35.4%(34/96),Grade 1占41.7%(40/96),Grade 2占8.3%(8/96),Grade 3占2.1%(2/96)。
- 诊断率:钳夹活检77.0%(74/96),冷冻活检79.1%(76/96),总体87.5%(84/96)。
- 冷冻活检在10例患者中提供唯一诊断,标本面积显著大于钳夹活检(7.06 vs. 2.46 mm²;p < 0.001)。
- 冷冻活检多重基因检测成功率为95.8%(23/24)。
临床怎么用
- 对于疑似肺癌的周围型肺病变,可考虑经治疗型支气管镜工作通道使用1.1mm冷冻探头进行活检,以获取更大标本并提高诊断率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVE: Cryobiopsy using a 1.1-mm cryoprobe through a therapeutic bronchoscope with a 3.0-mm working channel permits en bloc retrieval of the cryoprobe and guide sheath while the bronchoscope remains wedged in the target bronchus, potentially facilitating immediate haemostatic control. This study investigated the safety and efficacy of this technique. METHODS: This prospective observational study enrolled patients with peripheral pulmonary lesions suspected of lung cancer who underwent forceps biopsy (FB), followed by cryobiopsy using a 1.1-mm cryoprobe through a therapeutic bronchoscope with a 3.0-mm working channel. The primary endpoint was procedural safety, as assessed by bleeding grade. The secondary endpoints included procedure-related complications, diagnostic yield, specimen size, procedural success rate, and biomarker analysis success rate. RESULTS: Of 100 enrolled patients, 96 were included in the analysis, and 84 underwent cryobiopsy. Bleeding severity was Grade 0 in 35.4% (34 of 96), Grade 1 in 41.7% (40 of 96), Grade 2 in 8.3% (8 of 96), and Grade 3 in 2.1% (2 of 96) of patients. Diagnostic yields were 77.0% (74 of 96) for FB and 79.1% (76 of 96) for cryobiopsy, with an overall yield of 87.5% (84 of 96). Cryobiopsy provided the sole diagnosis in 10 patients and yielded significantly larger specimens than FB (7.06 vs. 2.46 mm2; p < 0.001). The success rate of multiplex genetic testing was 95.8% for cryobiopsy (23 of 24). CONCLUSION: Direct retrieval of cryobiopsy specimens through the working channel of a therapeutic bronchoscope is safe and feasible, yielding larger specimens with complementary diagnostic value.
引用
- Takigawa Y, Oki M, Sato K, et al. Safety and Efficacy of Direct Cryobiopsy Specimen Retrieval Through the 3.0-mm Working Channel of a Therapeutic Bronchoscope Using a 1.1-mm Cryoprobe: A Multicentre Prospective Observational Study. Respirology. 2026. PMID: 42749302. doi:10.1002/resp.70314
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。