年龄校正与临床概率校正D-二聚体截断值在疑似肺栓塞中的安全性:系统综述与荟萃分析
该系统综述与荟萃分析纳入6项前瞻性诊断管理研究共12194例疑似肺栓塞患者,评估自适应D-二聚体策略的诊断失败率。结果显示,未行CTPA即排除肺栓塞的患者总体失败率为0.12%(95%CI 0.06-0.26%),自适应窗口内失败率为0.50%(95%CI 0.20-1.11%),算法效率为60.8%(95%CI 49.2-71.2%)。
要点
- 自适应D-二聚体策略排除肺栓塞的总体诊断失败率低(0.12%)。
- D-二聚体位于自适应窗口(>500 ng/mL但低于自适应阈值)时失败率为0.50%。
- 自适应策略的汇总算法效率为60.8%,可减少CTPA使用。
核心结论
- 自适应D-二聚体策略诊断急性肺栓塞的诊断失败率可接受性低,在自适应窗口内的患者亦然。
研究设计与样本
- 系统综述与荟萃分析,纳入6项前瞻性诊断管理研究,共12194例疑似肺栓塞患者。
主要发现
- 研究间肺栓塞患病率为7.0%至19.2%。
- 未行CTPA即排除肺栓塞的患者中,失败率范围为0.00%至0.27%,汇总失败率为0.12%(95%CI 0.06-0.26%;I2=0%)。
- 自适应D-二聚体窗口内的汇总失败率为0.50%(95%CI 0.20-1.11%;I2=0%)。
- 汇总算法效率为60.8%(95%CI 49.2-71.2;I2=99.3%)。
关键数值与推荐
- 诊断失败定义为3个月内发生静脉血栓栓塞症或肺栓塞相关或不明原因死亡。
- 自适应窗口定义为D-二聚体>500 ng/mL但低于自适应阈值。
- 纳入标准:前瞻性诊断管理研究,招募至少50例疑似肺栓塞患者,使用自适应D-二聚体阈值指导胸部影像学检查。
临床怎么用
- 在疑似肺栓塞患者中,采用年龄校正或临床概率校正的D-二聚体阈值可安全排除肺栓塞,包括D-二聚体位于自适应窗口的患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Adaptive D-dimer strategies for rule out of pulmonary embolism (PE) have been proposed to improve the efficiency of conventional fixed '500' D-dimer thresholds. Validations of adaptive D-dimer strategies post-hoc in cohorts managed according to the fixed D-dimer threshold seems to questions their safety. Research Question What is the proportion of diagnostic failures in patients with suspected PE managed according to an adaptive strategy who have a D-dimer level >500 ng/mL but below the adaptive threshold, defined as the "adaptive window"? STUDY DESIGN AND METHODS: We conducted a systematic review and meta-analysis of prospective diagnostic management studies that recruited at least 50 patients with suspected PE and in which an adaptive D-dimer threshold was used to guide chest imaging. Diagnostic failure was defined as venous thromboembolism or PE-related or unexplained death occurring within 3 months. Exclusion criteria were: i) data required to calculate the primary outcome were unavailable; or ii) the study included only children or pregnant women. Study-specific proportions were pooled using a random-effects meta-analysis. RESULTS: Six studies (12,194 patients) were included, with a PE prevalence ranging from 7.0% to 19.2%. Among all patients in whom PE was ruled out without CTPA using adaptive D-dimer strategies, failure rates ranged from 0.00% to 0.27%, with a pooled overall failure rate of 0.12% (95%CI 0.06-0.26%; I2 0%). The pooled failure rate in the adaptive D-dimer window was 0.50% (95%CI 0.20-1.11%; I2 0%). Pooled algorithm-based efficiency was 60.8% (95%CI 49.2-71.2; I2 99.3%). INTERPRETATION: The diagnostic failure rate of adaptive strategies for the diagnosis of acute PE is acceptably low, also in patients with a D-dimer in the adaptive window.
引用
- Graziani M, Akerboom B, Freund Y, et al. Safety of Age-Adjusted and Clinical Probability-Adjusted D-dimer Cut-offs in Suspected Pulmonary Embolism: A Systematic Review and Meta-Analysis. Chest. 2026. PMID: 42790624. doi:10.1016/j.chest.2026.09.030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。