文献速递慢阻肺

CT气道黏液栓与保留肺功能及COPD人群呼吸结局的关系:中国人群发现

Association between Airway Mucus Plugs on Computed Tomography and Respiratory Outcomes in Participants with COPD and with Preserved Spirometry: Findings from a Chinese Population.
PubMed 文献 · Am J Respir Crit Care Med · 2026-09-25

基于中国社区前瞻性队列(1939例,COPD 847例、保留肺功能1092例,3年随访完成率89%),评估CT气道黏液栓与呼吸结局的关联。保留肺功能者中,1-2个或≥3个肺段黏液栓与急性加重风险升高相关;≥3个黏液栓者肺功能定义COPD发生率18.2% vs 7.6%,FEV1/FVC年下降更快。COPD者中≥3个黏液栓与总加重及中重度加重风险升高相关。

要点

  • 保留肺功能者中≥3个肺段黏液栓与COPD发生风险及FEV1/FVC加速下降相关
  • COPD者中≥3个肺段黏液栓与总加重及中重度加重风险升高相关
  • 黏液栓或可作为保留肺功能人群呼吸结局风险的影像标志物

核心结论

  • 基线气道黏液栓可能与保留肺功能者和COPD者未来急性加重相关,并可能提示保留肺功能者肺功能定义COPD发生风险增加。

研究设计与样本

  • 前瞻性社区队列研究,2019年7月至2024年9月在中国开展,纳入完成基线问卷、肺功能及胸部CT并随访的参与者。
  • 共纳入1939例参与者(COPD 847例,保留肺功能1092例),1740例(89%)完成3年随访。
  • 黏液栓按累及0、1-2或≥3个肺段分类,呼吸结局包括急性加重、肺功能下降及肺功能定义COPD发生。

主要发现

  • 保留肺功能者中,1-2个黏液栓者急性加重风险RR 1.22(95%CI 1.01-1.48),≥3个者RR 1.42(95%CI 1.11-1.81),均高于无黏液栓者。
  • 保留肺功能者中,≥3个黏液栓者肺功能定义COPD发生率为18.2% vs 7.6%(RR 1.71,95%CI 1.05-2.78),且FEV1/FVC年下降更快。
  • COPD者、轻中度COPD者或无症状COPD者中,≥3个黏液栓与总加重及中重度加重风险升高相关。

临床怎么用

  • 对保留肺功能或COPD患者,胸部CT发现≥3个肺段黏液栓可提示未来急性加重及肺功能下降风险较高。
  • 保留肺功能者检出黏液栓时,可考虑更密切随访肺功能及急性加重事件。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

RATIONALE: Airway mucus plugs are a prognostic marker in moderate-to-very severe chronic obstructive pulmonary disease (COPD), but their association with respiratory outcomes has been insufficiently evaluated among participants with preserved spirometry and asymptomatic COPD. OBJECTIVES: To investigate the association between mucus plugs and respiratory outcomes among participants with COPD and with preserved spirometry. METHODS: This prospective community-based cohort study was conducted in China, from July 2019 to September 2024. Eligible participants completed baseline questionnaires, spirometry, and chest CT with follow-up. Mucus plugs were categorized as affecting 0, 1-2, or ≥ 3 lung segments. Respiratory outcomes included exacerbations, lung function decline, and spirometry-defined COPD development. MEASUREMENTS AND MAIN RESULTS: Overall, 1,939 participants (COPD: 847; preserved spirometry: 1,092) were included, and 1,740 (89%) completed the 3-year follow-up. Among participants with preserved spirometry, those with 1-2 or ≥ 3 mucus plugs had a higher exacerbation risk (RR 1.22, 95%CI 1.01-1.48; RR 1.42, 95%CI 1.11-1.81, respectively) than those without mucus plugs. Participants with ≥3 mucus plugs had a higher risk of spirometry-defined COPD development (18.2% vs. 7.6%, RR 1.71, 95%CI 1.05-2.78) and faster annual decline in FEV1/FVC than those without mucus plugs. Among participants with COPD, with mild-to-moderate COPD, or with asymptomatic COPD, the presence of ≥ 3 mucus plugs were associated with a higher total and moderate-to-severe exacerbation risk. CONCLUSIONS: Baseline airway mucus plugs potentially associated with future exacerbations in participants with preserved spirometry and COPD, and may suggest an increased risk of spirometry-defined COPD development in those with preserved spirometry.

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

引用

  1. Wu F, Wu F, Xia T, et al. Association between Airway Mucus Plugs on Computed Tomography and Respiratory Outcomes in Participants with COPD and with Preserved Spirometry: Findings from a Chinese Population. Am J Respir Crit Care Med. 2026. PMID: 42789746. doi:10.1093/ajrccm/aamag521

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。