文献速递哮喘

计算流体动力学模型预测重度哮喘患者吸入性糖皮质激素沉积

Computational fluid dynamics model predictions of inhaled corticosteroid deposition in patients with severe asthma.
PubMed 文献 · Thorax · 2025-06-16

研究对28例重度哮喘患者行吸气相和呼气相胸部CT并检测2型炎症生物标志物,利用功能呼吸成像和计算流体动力学模拟细颗粒与超细颗粒ICS的胸腔内、中央及外周气道沉积。结果显示超细颗粒ICS各区域沉积均高于细颗粒ICS;气道壁增厚、管腔狭窄及痰嗜酸性粒细胞升高者中央与外周沉积比更高,细颗粒ICS到达外周气道更少,超细颗粒ICS未能完全抵消此差异。

要点

  • 超细颗粒ICS在胸腔内、中央及外周气道沉积均高于细颗粒ICS。
  • 气道壁增厚和管腔狭窄与更高的中央/外周沉积比相关。
  • 痰嗜酸性粒细胞升高者中央/外周沉积比更高,与颗粒大小无关。

核心结论

  • 在气道壁较厚、管腔较窄及2型炎症标志物升高的重度哮喘患者中,较小比例的细颗粒ICS到达外周气道,超细颗粒ICS未能完全改善此问题。

研究设计与样本

  • 28例重度哮喘患者同日完成全吸气相和全呼气相胸部CT及2型炎症生物标志物检测。
  • 采用功能呼吸成像和计算流体动力学模拟预测ICS沉积。

主要发现

  • 模拟沉积显示超细颗粒ICS在胸腔内、中央和外周气道均高于细颗粒ICS(均p<0.0001)。
  • 壁面积百分比增大和管腔面积减小与细颗粒ICS中央/外周沉积比正相关(r=0.60,p=0.0068)和负相关(r=-0.60,p=0.0072)。
  • 壁面积百分比增大和管腔面积减小与超细颗粒ICS中央/外周沉积比正相关(r=0.54,p=0.028)和负相关(r=-0.54,p=0.026)。
  • 痰嗜酸性粒细胞升高者中央/外周沉积比更高,细颗粒ICS p=0.045,超细颗粒ICS p=0.021。

临床怎么用

  • 评估重度哮喘患者气道形态和2型炎症标志物可能有助于理解ICS区域沉积差异。
  • 对于气道壁厚、管腔窄且2型炎症标志物升高者,需关注细颗粒ICS外周沉积不足的可能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Some patients with severe asthma have persistent type-2 inflammation despite being treated with high-dose inhaled corticosteroids (ICS). The variability in ICS deposition between patients with severe asthma is not well-understood and could contribute to this persistence. OBJECTIVES: To characterise and compare model-predicted deposition of fine-particle and extrafine-particle ICS in patients with severe asthma based on biomarkers of type-2 inflammation, airway morphology and airway function. METHODS: Twenty-eight patients with severe asthma performed full-inspiration and full-expiration chest CT on the same day that biomarkers of type-2 inflammation were measured. Functional respiratory imaging and computational fluid dynamics were used to simulate and predict intrathoracic, central and peripheral airway deposition, and central-to-peripheral airway deposition (C:P) ratio of fine-particle ICS (fluticasone-propionate HFA) (ICSFP) and extrafine-particle ICS (beclomethasone-dipropionate HFA) (ICSEFP). CT-derived wall area percent (WA%), lumen area (LA) and mucus burden were quantified to characterise airway morphology. RESULTS: Simulated deposition of ICSEFP was higher than ICSFP in the intrathoracic, central and peripheral airways (all p<0.0001). Greater WA% and smaller LA were correlated with greater C:P ratio of ICSFP (r=0.60, p=0.0068; r=-0.60, p=0.0072) and ICSEFP (r=0.54, p=0.028; r=-0.54, p=0.026). Participants with elevated sputum eosinophils had a greater C:P ratio, irrespective of particle size (ICSFP, p=0.045; ICSEFP, p=0.021). CONCLUSIONS: In severe asthma patients with thicker airway walls, narrower airway lumens and elevated biomarkers of type-2 inflammation, a smaller ratio of ICSFP reached the peripheral airways. ICSEFP did not fully mitigate this. Patient-specific airway morphology may impact regional ICS deposition and contribute to persistent inflammation.

来源:Thorax,查看原文。版权归原作者所有。

引用

  1. Ragunayakam N, Thakar A, Sadafi H, et al. Computational fluid dynamics model predictions of inhaled corticosteroid deposition in patients with severe asthma. Thorax. 2025. PMID: 40147931. doi:10.1136/thorax-2024-222444

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。