改良袖带漏气试验预测有创机械通气患者再插管风险:多中心随机对照试验
本研究为前瞻性多中心随机对照试验,纳入536例有创机械通气患者,比较改良袖带漏气试验与传统方法对再插管风险的预测能力。主要终点48小时内再插管率两组无差异,但改良组拔管后24小时内喘鸣发生率更高(5.22% vs 1.49%),且有创机械通气时间更短。结论提示改良法可能更好地预测拔管后喘鸣,尤其对机械通气≥6天者,但未降低再插管率和死亡率。
要点
- 改良袖带漏气试验未降低48小时内再插管率。
- 改良组拔管后24小时内喘鸣发生率更高(5.22% vs 1.49%)。
- 改良组有创机械通气时间更短(137小时 vs 159小时)。
核心结论
- 改良袖带漏气试验可能更好地预测拔管后24小时内喘鸣,尤其对机械通气≥6天者,但未显示降低再插管率和死亡率。
研究设计与样本
- 前瞻性、多中心、单盲随机对照试验,共随机分配536例有创机械通气患者至改良袖带漏气试验组(n=268)或对照组(n=268)。
主要发现
- 48小时内再插管率两组无差异。
关键数值与推荐
- 主要终点为拔管后48小时内再插管发生率。
- 次要终点包括再插管实际发生率、拔管后喘鸣发生率、有创机械通气时间等。
临床怎么用
- 改良袖带漏气试验可用于预测拔管后喘鸣,尤其对机械通气≥6天患者,但不应期望其降低再插管率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The cuff leak test (CLT) is an important tool to assess the risk of upper airway obstruction after extubation. RESEARCH QUESTION: Does a modified CLT approach have superior ability in predicting reintubation compared with the traditional method? STUDY DESIGN AND METHODS: This was a prospective, multicenter, randomized controlled trial. The primary end point was the incidence of the need for reintubation within 48 hours of extubation. Secondary end points included, among others, the actual incidence of reintubation, the incidence of postextubation stridor (PES), and the duration of invasive mechanical ventilation (IMV). RESULTS: A total of 536 patients were randomized to either the modified CLT group (n = 268) or the control group (n = 268). The incidence of reintubation within 48 hours of extubation did not differ between the groups. PES within 24 hours of extubation was more frequent in the modified CLT group than in the control group (5.22% vs 1.49%; OR, 0.275 [95% CI, 0.089-0.846]; P = .028). The IMV duration was shorter in the modified CLT group than in the control group (137 hours [74, 218] vs 159 hours [95, 252]; OR, 1.001 [95% CI, 1.000-1.002]; P = .046). In the patients with IMV duration ≥ 6 days, the incidence of PES was 2.95% in the modified CLT group and 0.74% in the control group (OR, 0.203 [95% CI, 0.042-0.975]; P = .048). INTERPRETATION: Compared with the control group, the modified CLT approach might better predict PES within 24 hours of extubation, especially for patients with IMV duration longer than 6 days, but it was not shown to decrease the reintubation incidence and mortality. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT05550220; URL: clinicaltrials.gov.
引用
- Tang X, Gu YM, Shi Y, et al. Modified Cuff Leak Test for Predicting the Risk of Reintubation in Patients With Invasive Mechanical Ventilation: A Multicenter, Single-Anonymized, Randomized Controlled Trial. Chest. 2025. PMID: 39922534. doi:10.1016/j.chest.2025.01.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。