中国低剂量CT筛查中纯磨玻璃肺结节直径阈值研究
基于广州肺癌筛查项目的回顾性分析,评估5–10 mm直径阈值对纯磨玻璃结节恶性诊断效能的影响。将恶性结节分为三组,发现阈值升至8 mm可改善诊断性能,决策曲线分析显示8 mm模型临床效用更优。
要点
- 阈值从5 mm升至8 mm,特异度与阳性预测值提高但敏感度下降。
- 阈值从5 mm升至7 mm可提升三组恶性结节的AUC。
- 决策曲线分析显示8 mm阈值模型临床效用更优。
核心结论
- 将纯磨玻璃结节阳性直径阈值提高至8 mm可增强诊断性能。
研究设计与样本
- 广州肺癌筛查项目的回顾性分析,评估5–10 mm阈值对恶性纯磨玻璃结节的诊断效能。
主要发现
- 在「MIA+IA」组,阈值从5 mm升至8 mm,特异度从60.97%升至88.85%(p<0.001),阳性预测值从5.87%升至14.88%(p<0.001),敏感度从94.44%降至75.56%(p<0.001)。
- 阈值从8 mm进一步升高,敏感度从75.56%降至60.00%(p<0.001),特异度从88.85%升至93.47%(p<0.001),阳性预测值从14.88%升至19.15%(p<0.001)。
- 阈值从5 mm升至7 mm,「MIA+IA」组AUC从0.711升至0.829,「AAH+AIS+MIA+IA」组从0.748升至0.804,「IA-only」组从0.783升至0.833。
- 阈值从7 mm升至10 mm,「MIA+IA」组AUC从0.829降至0.767,「AAH+AIS+MIA+IA」组从0.804降至0.744,「IA-only」组从0.833降至0.800。
- 决策曲线分析显示8 mm预测模型相比其他阈值模型具有更大临床效用。
临床怎么用
- 在低剂量CT筛查中,对纯磨玻璃结节采用8 mm作为阳性阈值可能优化恶性检出与假阳性的平衡。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Limited research exists on screening thresholds for low-dose CT in detecting malignant pure ground-glass lung nodules (pGGNs) in the Chinese population. MATERIALS AND METHODS: A retrospective analysis of the Guangzhou Lung-Care programme was conducted, retrieving average transverse diameter, location, histopathology, frequency and follow-up intervals. Diagnostic performances for 'lung cancers' were evaluated using areas under the curve (AUCs), decision curve analysis (DCA), sensitivities and specificities, with thresholds ranging from 5 mm to 10 mm. We divide malignant pGGNs into three groups: (1) minimally invasive adenocarcinoma (MIA) and invasive adenocarcinoma (IA), (2) atypical adenomatous hyperplasia (AAH) and adenocarcinoma in situ (AIS) and MIA and IA and (3) IA-only. RESULTS: In 'MIA+IA', increasing the threshold from 5 mm to 8 mm improved specificity (60.97% to 88.85%, p<0.001) and positive predictive values (PPVs; 5.87% to 14.88%, p<0.001), but decreased sensitivity (94.44% to 75.56%, p<0.001). Further raising threshold from 8 mm reduced sensitivity (75.56% to 60.00%, p<0.001), while slightly increasing specificity (88.85% to 93.47%, p<0.001) and PPVs (14.88% to 19.15%, p<0.001). Increasing threshold from 5 mm to 7 mm enhanced the AUC for 'MIA+IA' (from 0.711 to 0.829), 'AAH+AIS+MIA+IA' (from 0.748 to 0.804) and 'IA-only' (from 0.783 to 0.833). At 8 mm, the AUCs for these categories were similar. However, increasing the threshold from 7 mm to 10 mm resulted in reduced AUCs for 'MIA+IA' (0.829 to 0.767), 'AAH+AIS+MIA+IA' (0.804 to 0.744) and 'IA-only' (0.833 to 0.800). DCA reveals that the 8 mm predictive model demonstrates greater clinical utility compared with models with other thresholds. CONCLUSIONS: Increasing the diameter threshold for positive results for pGGNs, up to 8 mm could enhance diagnostic performance. TRIAL REGISTRATION NUMBER: NCT04938804.
引用
- Ye W, Fu W, Li C, et al. Diameter thresholds for pure ground-glass pulmonary nodules at low-dose CT screening: Chinese experience. Thorax. 2025. PMID: 39689940. doi:10.1136/thorax-2024-221642
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。