文献速递呼吸危重症与机械通气

家庭机械通气中口鼻面罩与鼻面罩的比较:观察性队列与台架研究

Comparison of oronasal and nasal masks in home mechanical ventilation: an observational cohort and bench study.
PubMed 文献 · Eur Respir J · 2025-01-02

该前瞻性观察性队列纳入800例长期家庭无创通气患者,84%使用口鼻面罩。47%患者发生中至极重度面罩相关副作用,18%发生重至极重度副作用,且与日间PaCO2较差、主观睡眠质量差及生活质量差相关。口鼻面罩副作用报告率高于鼻面罩,台架研究显示鼻面罩更稳定。

要点

  • 面罩相关副作用常见,47%为中至极重度,18%为重至极重度。
  • 副作用与日间PaCO2较差、睡眠质量差及生活质量差相关。
  • 鼻面罩副作用报告较少且台架稳定性更优,或可作一线接口。

核心结论

  • 面罩相关副作用频繁发生且与较差结局相关,鼻面罩耐受性可能更优并应作为一线接口。

研究设计与样本

  • 前瞻性观察性队列纳入800例长期家庭无创通气稳定期患者,另进行连接三维打印头模与人工肺的台架研究。

主要发现

  • 84%患者使用口鼻面罩;47%发生中至极重度面罩相关副作用,18%发生重至极重度副作用。
  • 副作用与日间动脉血二氧化碳分压较差(p=0.005)、主观睡眠质量较差(p=0.003)及生活质量较差(p<0.001)相关。
  • 口鼻面罩相比鼻面罩更常报告面罩相关副作用(p=0.023)。
  • 台架研究显示鼻面罩比口鼻面罩更稳定(p<0.001)。

临床怎么用

  • 对家庭无创通气患者应常规评估面罩相关副作用,并考虑将鼻面罩作为一线接口以改善耐受性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In patients with chronic respiratory failure, home non-invasive ventilation (NIV) is delivered through oronasal or nasal masks. Masks are a cornerstone for NIV success but can be associated with side-effects. However, the type, frequency and consequences of these side-effects are unknown. Here, we aimed to study the prevalence, nature and impact of mask-related adverse events in a cohort of stable patients. We then investigated differences between oronasal and nasal masks both in our cohort and in a bench study. METHODS: This was a prospective observational cohort including patients established on long-term NIV admitted for their elective review. Data regarding mask-related side-effects were assessed using a structured questionnaire. Our bench study was performed using a three-dimensional printed head connected to an artificial lung. RESULTS: 800 patients were included, of whom 84% had an oronasal mask. Moderate to very severe mask-related side-effects occurred in 47% of patients and severe to very severe side-effects occurred in 18% of patients. Side-effects were associated with poorer daytime arterial partial pressure of carbon dioxide (p=0.005), poorer subjective sleep quality (p=0.003) and poorer quality of life (p<0.001). Mask-related side-effects were more frequently reported with the use of oronasal masks compared to nasal masks (p=0.023). Our bench study showed that nasal masks were more stable than oronasal masks (p<0.001). CONCLUSIONS: Mask-related side-effects are frequent and associated with poorer outcomes. Our data suggest that nasal masks may have a better tolerance profile and should be used as a first-line interface.

来源:Eur Respir J,查看原文。版权归原作者所有。

引用

  1. Fresnel E, Caillard C, Lebret M, et al. Comparison of oronasal and nasal masks in home mechanical ventilation: an observational cohort and bench study. Eur Respir J. 2025. PMID: 39401860. doi:10.1183/13993003.02010-2023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。