基于心电图的人工智能算法用于肺动脉高压早期检测
本研究开发并外部验证了基于标准12导联心电图的卷积神经网络算法PH-EDA,用于筛查肺动脉高压。在Mayo Clinic和VUMC的诊断数据集AUC分别为0.92和0.88,在诊断前6-18个月的数据集AUC为0.86和0.81,显示早期检测潜力。
要点
- PH-EDA基于12导联心电图,可分类为PH可能或PH不可能。
- 诊断时AUC在Mayo为0.92,VUMC为0.88;诊断前6-18个月为0.86和0.81。
- 诊断前5年AUC最低仍达0.79(Mayo)和0.73(VUMC)。
核心结论
- PH-EDA可在诊断时及诊断前6-18个月检测肺动脉高压,有望加速诊断和管理。
研究设计与样本
- 回顾性开发卷积神经网络,使用Mayo Clinic的ECG电压-时间数据,患者经右心导管或超声心动图分类为PH可能或对照。
- 训练集、验证集、测试集按48%、12%、40%随机划分,共39 823例PH可能患者和219 404例对照。
- 外部验证在Vanderbilt University Medical Center进行,使用诊断数据集和诊断前6-18个月及长达5年的ECG。
主要发现
- 诊断测试集AUC:Mayo Clinic 0.92(n=16 175/87 998 PH可能/对照),VUMC 0.88(n=6045/24 256)。
- 诊断前6-18个月测试集AUC:Mayo Clinic 0.86,VUMC 0.81。
- 诊断前长达5年AUC最低值:Mayo Clinic 0.79,VUMC 0.73。
临床怎么用
- PH-EDA可作为基于标准12导联心电图的肺动脉高压筛查工具,辅助早期识别和转诊。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Early diagnosis of pulmonary hypertension (PH) is critical for effective treatment and management. We aimed to develop and externally validate an artificial intelligence algorithm that could serve as a PH screening tool, based on analysis of a standard 12-lead ECG. METHODS: The PH Early Detection Algorithm (PH-EDA) is a convolutional neural network developed using retrospective ECG voltage-time data, with patients classified as "PH-likely" or "PH-unlikely" (controls) based on right heart catheterisation or echocardiography. In total, 39 823 PH-likely patients and 219 404 control patients from Mayo Clinic were randomly split into training (48%), validation (12%) and test (40%) sets. ECGs taken within 1 month of PH diagnosis (diagnostic dataset) were used to train the PH-EDA at Mayo Clinic. Performance was tested on diagnostic ECGs within the test sets from Mayo Clinic (n=16 175/87 998 PH-likely/controls) and Vanderbilt University Medical Center (VUMC; n=6045/24 256 PH-likely/controls). In addition, performance was tested on ECGs taken 6-18 months (pre-emptive dataset), and up to 5 years prior to a PH diagnosis at both sites. RESULTS: Performance testing yielded an area under the receiver operating characteristic curve (AUC) of 0.92 and 0.88 in the diagnostic test sets at Mayo Clinic and VUMC, respectively, and 0.86 and 0.81, respectively, in the pre-emptive test sets. The AUC remained a minimum of 0.79 at Mayo Clinic and 0.73 at VUMC up to 5 years before diagnosis. CONCLUSION: The PH-EDA can detect PH at diagnosis and 6-18 months prior, demonstrating the potential to accelerate diagnosis and management of this debilitating disease.
引用
- DuBrock HM, Wagner TE, Carlson K, et al. An electrocardiogram-based AI algorithm for early detection of pulmonary hypertension. Eur Respir J. 2024. PMID: 38936966. doi:10.1183/13993003.00192-2024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。