基于电阻抗断层成像的大手术后通气模式研究
该前瞻性研究纳入128例大手术后入ICU接受机械通气的高危患者,用电阻抗断层成像(EIT)识别出三种通气模式表型:腹侧通气为主型(32%)、均匀通气型(41%)和背侧通气为主型(27%)。腹侧和背侧为主型的术后肺部并发症评分中位数均高于均匀型,且腹侧为主型脱机时间和ICU住院时间更长。
要点
- EIT可识别术后三种通气模式:腹侧为主、均匀、背侧为主。
- 非均匀通气模式与术后肺部并发症评分升高相关。
- 腹侧为主型脱机时间和ICU住院时间更长。
核心结论
- ICU入科时EIT显示的非均匀通气模式与术后肺部并发症、延迟脱机及ICU住院时间延长相关。
主要发现
- EIT揭示三种通气模式表型:表型1腹侧通气为主占32%(n=41),表型2均匀通气占41%(n=52),表型3背侧通气为主占27%(n=35)。
- 表型1和表型3的术后肺部并发症评分中位数高于表型2。
- 表型1的机械通气脱机时间中位数长于表型2。
- 表型1的ICU住院时间中位数长于表型2。
- 表型1和表型3的氧疗脱机时间中位数长于表型2。
临床怎么用
- 对术后入ICU机械通气的高危患者,可考虑用EIT早期识别非均匀通气模式以评估术后肺部并发症和脱机风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Rationale: General anesthesia and mechanical ventilation have negative impacts on the respiratory system, causing heterogeneous distribution of lung aeration, but little is known about the ventilation patterns of postoperative patients and their association with clinical outcomes. Objectives: To clarify the phenotypes of ventilation patterns along a gravitational direction after surgery by using electrical impedance tomography (EIT) and to evaluate their association with postoperative pulmonary complications (PPCs) and other relevant clinical outcomes. Methods: Adult postoperative patients at high risk for PPCs, receiving mechanical ventilation on ICU admission (N = 128), were prospectively enrolled between November 18, 2021 and July 18, 2022. PPCs were prospectively scored until hospital discharge, and their association with phenotypes of ventilation patterns was studied. The secondary outcomes were the times to wean from mechanical ventilation and oxygen use and the length of ICU stay. Measurements and Main Results: Three phenotypes of ventilation patterns were revealed by EIT: phenotype 1 (32% [n = 41], a predominance of ventral ventilation), phenotype 2 (41% [n = 52], homogeneous ventilation), and phenotype 3 (27% [n = 35], a predominance of dorsal ventilation). The median PPC score was higher in phenotype 1 and phenotype 3 than in phenotype 2. The median time to wean from mechanical ventilation was longer in phenotype 1 versus phenotype 2. The median duration of ICU stay was longer in phenotype 1 versus phenotype 2. The median time to wean from oxygen use was longer in phenotype 1 and phenotype 3 than in phenotype 2. Conclusions: Inhomogeneous ventilation patterns revealed by EIT on ICU admission were associated with PPCs, delayed weaning from mechanical ventilation and oxygen use, and a longer ICU stay.
引用
- Iwata H, Yoshida T, Hoshino T, et al. Electrical Impedance Tomography-based Ventilation Patterns in Patients after Major Surgery. Am J Respir Crit Care Med. 2024. PMID: 38346178. doi:10.1164/rccm.202309-1658OC
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。