文献速递呼吸危重症与机械通气

高与低呼气末正压对存在强吸气努力的ARDS辅助通气患者的影响:随机交叉试验

High vs Low PEEP in Patients With ARDS Exhibiting Intense Inspiratory Effort During Assisted Ventilation: A Randomized Crossover Trial.
PubMed 文献 · Chest · 2024-01-29

高PEEP对吸气努力和肺应力的影响存在个体差异,取决于其对呼吸系统顺应性的改变;仅当高PEEP增加肺/呼吸系统顺应性时,才可能减轻自发性肺损伤风险。

要点

  • 高PEEP对吸气努力的影响因人而异,取决于呼吸系统顺应性的变化。
  • 高PEEP仅当增加肺/呼吸系统顺应性时,才可能减轻自发性肺损伤风险。
  • 高PEEP导致潮气量向背侧肺区再分布,降低腹侧动态应变。

核心结论

  • 高PEEP对吸气努力和肺应力的影响存在个体间差异,取决于其对呼吸系统和肺顺应性的不同效应,而后者由肺泡过度充气程度决定。
  • 仅当高PEEP增加肺/呼吸系统顺应性时,才可能有助于减轻自发性肺损伤风险。

研究设计与样本

  • 患者随机接受四种通气设置序列:PEEP 5 cm H2O或PEEP 15 cm H2O,分别联合同步(压力支持通气)或非同步(压力控制间歇指令通气)吸气辅助。
  • 采用食管测压和阻断法评估ΔPes及呼吸系统、肺和胸壁力学;采用电阻抗断层成像评估PEEP诱导的肺泡复张和过度充气、肺动态应变及潮气量分布。

主要发现

  • 高PEEP与低PEEP相比,ΔPes无系统性差异:压力支持通气下中位数20 cm H2O(IQR 15-24)vs 15 cm H2O(IQR 13-23),P = .24;压力控制间歇指令通气下中位数20(IQR 18-23)vs 19(IQR 17-25),P = .67。
  • 呼吸系统和跨肺驱动压、潮气量、肺/胸壁力学及摆动幅度在研究阶段间无差异。
  • 高PEEP导致ΔPes、呼吸系统驱动压和跨肺驱动压降低或升高,取决于其增加或降低呼吸系统顺应性(r = -0.85, P < .001; r = -0.75, P < .001; r = -0.80, P < .001)。
  • PEEP诱导的呼吸系统顺应性变化由其肺成分驱动,并取决于PEEP诱导的肺泡过度充气程度(r = -0.66, P = .006)。
  • 高PEEP引起不同程度的复张和潮气量向背侧肺区的系统性再分布,从而降低腹侧动态应变(压力支持通气:中位数0.49, IQR 0.37-0.83 vs 0.96, IQR 0.62-1.56, P = .003;压力控制间歇指令通气:中位数0.65, IQR 0.42-1.31 vs 1.14, IQR 0.79-1.52, P = .002)。

关键数值与推荐

  • 纳入标准:Pao2/Fio2 ≤ 200 mm Hg且ΔPes ≥ 10 cm H2O。
  • 高PEEP定义为15 cm H2O,低PEEP定义为5 cm H2O。

临床怎么用

  • 高PEEP对吸气努力和肺应力的效应需个体化评估,不能一概而论。
  • 若高PEEP能增加呼吸系统/肺顺应性,可能有助于减轻自发性肺损伤风险;若降低顺应性则可能不利。
  • 可通过监测呼吸系统顺应性变化来判断高PEEP对患者的潜在获益。

局限性

  • 研究为随机交叉试验,干预时间较短,长期临床结局未评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Positive end-expiratory pressure (PEEP) can potentially modulate inspiratory effort (ΔPes), which is the major determinant of self-inflicted lung injury. RESEARCH QUESTION: Does high PEEP reduce ΔPes in patients with moderate-to-severe ARDS on assisted ventilation? STUDY DESIGN AND METHODS: Sixteen patients with Pao2/Fio2 ≤ 200 mm Hg and ΔPes ≥ 10 cm H2O underwent a randomized sequence of four ventilator settings: PEEP = 5 cm H2O or PEEP = 15 cm H2O + synchronous (pressure support ventilation [PSV]) or asynchronous (pressure-controlled intermittent mandatory ventilation [PC-IMV]) inspiratory assistance. ΔPes and respiratory system, lung, and chest wall mechanics were assessed with esophageal manometry and occlusions. PEEP-induced alveolar recruitment and overinflation, lung dynamic strain, and tidal volume distribution were assessed with electrical impedance tomography. RESULTS: ΔPes was not systematically different at high vs low PEEP (pressure support ventilation: median, 20 cm H2O; interquartile range (IQR), 15-24 cm H2O vs median, 15 cm H2O; IQR, 13-23 cm H2O; P = .24; pressure-controlled intermittent mandatory ventilation: median, 20; IQR, 18-23 vs median, 19; IQR, 17-25; P = .67, respectively). Similarly, respiratory system and transpulmonary driving pressures, tidal volume, lung/chest wall mechanics, and pendelluft extent were not different between study phases. High PEEP resulted in lower or higher ΔPes, respiratory system driving pressure, and transpulmonary driving pressure according to whether this increased or decreased respiratory system compliance (r = -0.85, P < .001; r = -0.75, P < .001; r = -0.80, P < .001, respectively). PEEP-induced changes in respiratory system compliance were driven by its lung component and were dependent on the extent of PEEP-induced alveolar overinflation (r = -0.66, P = .006). High PEEP caused variable recruitment and systematic redistribution of tidal volume toward dorsal lung regions, thereby reducing dynamic strain in ventral areas (pressure support ventilation: median, 0.49; IQR, 0.37-0.83 vs median, 0.96; IQR, 0.62-1.56; P = .003; pressure-controlled intermittent mandatory ventilation: median, 0.65; IQR, 0.42-1.31 vs median, 1.14; IQR, 0.79-1.52; P = .002). All results were consistent during synchronous and asynchronous inspiratory assistance. INTERPRETATION: The impact of high PEEP on ΔPes and lung stress is interindividually variable according to different effects on the respiratory system and lung compliance resulting from alveolar overinflation. High PEEP may help mitigate the risk of self-inflicted lung injury solely if it increases lung/respiratory system compliance. TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT04241874; URL: www. CLINICALTRIALS: gov.

来源:Chest,查看原文。版权归原作者所有。

引用

  1. Bello G, Giammatteo V, Bisanti A, et al. High vs Low PEEP in Patients With ARDS Exhibiting Intense Inspiratory Effort During Assisted Ventilation: A Randomized Crossover Trial. Chest. 2024. PMID: 38295949. doi:10.1016/j.chest.2024.01.040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。