高气道闭合压与危重机械通气患者呼吸困难及死亡率增加相关
本研究为法国10个ICU前瞻性队列的二次分析,纳入260例插管超过24小时的患者,测量P0.1并评估呼吸困难。结果显示P0.1升高与呼吸困难、90天死亡率增加及机械通气时间延长独立相关。
要点
- P0.1升高与呼吸困难独立相关,提示中枢呼吸驱动增强。
- P0.1>3.5 cm H2O者90天死亡率33%,高于P0.1 1.5-3.5者19%和<1.5者17%。
- 校正主要危险因素后,P0.1每升高1 cm H2O,90天死亡风险增加19%。
核心结论
- 在侵入性机械通气患者中,异常升高的P0.1可能提示呼吸困难,并与更高的死亡率和更长的机械通气时间相关。
研究设计与样本
- 法国10个ICU前瞻性队列研究的二次分析,纳入260例插管超过24小时、可沟通的机械通气患者,测量P0.1并评估呼吸困难。
主要发现
- 入组时中位机械通气时间4天,P0.1中位数1.9(1-3.5)cm H2O。
- 24%患者P0.1>3.5 cm H2O,37%在1.5-3.5 cm H2O之间,39%<1.5 cm H2O。
- 多变量线性回归中,与P0.1独立相关的因素包括呼吸困难(P=0.037)、呼吸频率(P<0.001)和PaO2(P=0.008)。
- 90天死亡率:P0.1>3.5 cm H2O组33%,1.5-3.5 cm H2O组19%,<1.5 cm H2O组17%(P=0.046)。
- 校正主要危险因素后,P0.1与90天死亡率独立相关(每1 cm H2O的风险比1.19,95%CI 1.04-1.37;P=0.011),并与更长的机械通气时间独立相关(每1 cm H2O的风险比1.10,95%CI 1.02-1.19;P=0.016)。
临床怎么用
- 对机械通气超过24小时的患者,可考虑监测P0.1以识别呼吸困难和高死亡风险患者。
- P0.1>3.5 cm H2O提示中枢呼吸驱动异常升高,需关注呼吸困难及预后。
局限性
- 本研究为二次分析,结果需在前瞻性研究中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Rationale: Airway occlusion pressure at 100 ms (P0.1) reflects central respiratory drive. Objectives: We aimed to assess factors associated with P0.1 and whether an abnormally low or high P0.1 value is associated with higher mortality and longer duration of mechanical ventilation (MV). Methods: We performed a secondary analysis of a prospective cohort study conducted in 10 ICUs in France to evaluate dyspnea in communicative MV patients. In patients intubated for more than 24 hours, P0.1 was measured with dyspnea as soon as patients could communicate and the next day. Measurements and Main Results: Among 260 patients assessed after a median time of ventilation of 4 days, P0.1 was 1.9 (1-3.5) cm H2O at enrollment, 24% had P0.1 values >3.5 cm H2O, 37% had P0.1 values between 1.5 and 3.5 cm H2O, and 39% had P0.1 values <1.5 cm H2O. In multivariable linear regression, independent factors associated with P0.1 were the presence of dyspnea (P = 0.037), respiratory rate (P < 0.001), and PaO2 (P = 0.008). Ninety-day mortality was 33% in patients with P0.1 > 3.5 cm H2O versus 19% in those with P0.1 between 1.5 and 3.5 cm H2O and 17% in those with P0.1 < 1.5 cm H2O (P = 0.046). After adjustment for the main risk factors, P0.1 was associated with 90-day mortality (hazard ratio per 1 cm H2O, 1.19 [95% confidence interval, 1.04-1.37]; P = 0.011). P0.1 was also independently associated with a longer duration of MV (hazard ratio per 1 cm H2O, 1.10 [95% confidence interval, 1.02-1.19]; P = 0.016). Conclusions: In patients receiving invasive MV, abnormally high P0.1 values may suggest dyspnea and are associated with higher mortality and prolonged duration of MV.
引用
- Le Marec J, Hajage D, Decavèle M, et al. High Airway Occlusion Pressure Is Associated with Dyspnea and Increased Mortality in Critically Ill Mechanically Ventilated Patients. Am J Respir Crit Care Med. 2024. PMID: 38319128. doi:10.1164/rccm.202308-1358OC
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。