文献速递肺结节与肺癌

标准尺寸活检钳与微型活检钳在EBUS引导下淋巴结活检中的标本质量比较:一项前瞻性研究

Comparison of the specimen quality of endobronchial ultrasound-guided intranodal forceps biopsy using standard-sized forceps versus mini forceps for lung cancer: A prospective study.
PubMed 文献 · Respirology · 2024-01-21

该前瞻性多中心研究纳入60例疑似晚期肺癌伴肺门/纵隔淋巴结肿大或需补充组织行生物标志物分析的患者,每例患者在同一淋巴结经EBUS-TBNA针道先后行微型活检钳活检(MFB)和标准尺寸活检钳活检(SFB)。结果显示SFB的高质量标本采样率显著更高,且平均标本尺寸为MFB的三倍,诊断率TBNA、MFB和SFB分别为91.7%、93.3%和96.7%。

要点

  • SFB获取高质量标本的采样率显著高于MFB。
  • SFB平均标本尺寸为MFB的三倍。
  • TBNA、MFB和SFB诊断率分别为91.7%、93.3%和96.7%。

核心结论

  • 标准尺寸活检钳活检(SFB)有助于获取质量和数量均充足的标本。

研究设计与样本

  • 前瞻性多中心研究,纳入3家机构的60例患者。
  • 患者为肺门/纵隔淋巴结肿大疑似晚期肺癌,或已确诊但需额外组织行生物标志物分析。
  • 每例患者在同一淋巴结经22G针EBUS-TBNA创建的针道先后行MFB和SFB各3或4次。
  • 由两名病理医师使用虚拟切片系统评估标本质量和大小,比较MFB与SFB的诊断性能。

主要发现

  • 60例入组患者中70.0%诊断为腺癌。
  • 最常靶向部位为下段气管旁淋巴结,其次为叶间淋巴结。
  • TBNA、MFB和SFB的诊断率分别为91.7%、93.3%和96.7%。
  • SFB组高质量标本采样率显著高于MFB组。
  • SFB平均标本尺寸为MFB的三倍。

临床怎么用

  • 在EBUS-TBNA针道基础上使用标准尺寸活检钳(1.9 mm)可获取更高质量和更大尺寸的标本,利于晚期肺癌治疗决策及生物标志物分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVE: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a diagnostic procedure with adequate performance; however, its ability to provide specimens of sufficient quality and quantity for treatment decision-making in advanced-stage lung cancer may be limited, primarily due to blood contamination. The use of a 0.96-mm miniforceps biopsy (MFB) permits true histological sampling, but the resulting small specimens are unsuitable for the intended applications. Therefore, we introduced a 1.9-mm standard-sized forceps biopsy (SFB) and compared its utility to that of MFB. METHODS: We prospectively enrolled patients from three institutions who presented with hilar/mediastinal lymphadenopathy and suspected advanced-stage lung cancer, or those who were already diagnosed but required additional tissue specimens for biomarker analysis. Each patient underwent MFB followed by SFB three or four times through the tract created by TBNA using a 22-gauge needle on the same lymph node (LN). Two pathologists assessed the quality and size of each specimen using a virtual slide system, and diagnostic performance was compared between the MFB and SFB groups. RESULTS: Among the 60 enrolled patients, 70.0% were diagnosed with adenocarcinoma. The most frequently targeted sites were the lower paratracheal LNs, followed by the interlobar LNs. The diagnostic yields of TBNA, MFB and SFB were 91.7%, 93.3% and 96.7%, respectively. The sampling rate of high-quality specimens was significantly higher in the SFB group. Moreover, the mean specimen size for SFB was three times larger than for MFB. CONCLUSION: SFB is useful for obtaining sufficient qualitative and quantitative specimens.

来源:Respirology,查看原文。版权归原作者所有。

引用

  1. Nakai T, Matsumoto Y, Ueda T, et al. Comparison of the specimen quality of endobronchial ultrasound-guided intranodal forceps biopsy using standard-sized forceps versus mini forceps for lung cancer: A prospective study. Respirology. 2024. PMID: 38246887. doi:10.1111/resp.14659

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。