电阻抗断层成像监测低氧性呼吸衰竭
该综述概述了电阻抗断层成像(EIT)的工作原理、主要指标及其在急性呼吸衰竭患者监测中的表现。EIT 可床旁无辐射评估区域肺通气和通气分布变化,帮助实现个体化机械通气,如寻找兼顾复张与过度膨胀的呼气末正压及评估俯卧位效果。EIT 的临床影响尚待探索,且存在空间分辨率有限等固有局限。
要点
- EIT 可床旁无辐射实时评估区域肺通气与通气分布。
- EIT 有助于在 ARDS 患者中个体化设置 PEEP 和评估俯卧位效果。
- EIT 个体化机械通气的临床影响尚待研究,且空间分辨率有限。
核心结论
- EIT 为 ICU 提供独特的无创床旁区域通气评估,可实现连续、无需操作者干预的诊断和机械通气常见问题的实时检测。
- EIT 个体化机械通气对临床结局的影响仍有待探索。
研究设计与样本
- 综述,检索范围未在摘要中报告。
主要发现
- 多项研究评估了 EIT 监测 ARDS 患者不同机械通气设置效果的表现,有助于更个体化的机械通气。
- EIT 可帮助临床医生找到兼顾复张与过度膨胀的呼气末正压。
- EIT 可评估俯卧位对通气分布的影响。
临床怎么用
- 可利用 EIT 床旁无辐射评估区域肺通气,指导个体化机械通气设置。
- 可借助 EIT 评估俯卧位等操作对通气分布的影响。
局限性
- EIT 存在固有局限,如空间分辨率有限。
- EIT 个体化机械通气的临床影响尚待探索。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Hypoxemic respiratory failure is one of the leading causes of mortality in intensive care. Frequent assessment of individual physiological characteristics and delivery of personalized mechanical ventilation (MV) settings is a constant challenge for clinicians caring for these patients. Electrical impedance tomography (EIT) is a radiation-free bedside monitoring device that is able to assess regional lung ventilation and changes in aeration. With real-time tomographic functional images of the lungs obtained through a thoracic belt, clinicians can visualize and estimate the distribution of ventilation at different ventilation settings or following procedures such as prone positioning. Several studies have evaluated the performance of EIT to monitor the effects of different MV settings in patients with acute respiratory distress syndrome, allowing more personalized MV. For instance, EIT could help clinicians find the positive end-expiratory pressure that represents a compromise between recruitment and overdistension and assess the effect of prone positioning on ventilation distribution. The clinical impact of the personalization of MV remains to be explored. Despite inherent limitations such as limited spatial resolution, EIT also offers a unique noninvasive bedside assessment of regional ventilation changes in the ICU. This technology offers the possibility of a continuous, operator-free diagnosis and real-time detection of common problems during MV. This review provides an overview of the functioning of EIT, its main indices, and its performance in monitoring patients with acute respiratory failure. Future perspectives for use in intensive care are also addressed.
引用
- Franchineau G, Jonkman AH, Piquilloud L, et al. Electrical Impedance Tomography to Monitor Hypoxemic Respiratory Failure. Am J Respir Crit Care Med. 2024. PMID: 38127779. doi:10.1164/rccm.202306-1118CI
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。